Siemens SIMATIC NET SCALANCE XCM-300 Product Manual page 62

Industrial ethernet switches
Hide thumbs Also See for SIMATIC NET SCALANCE XCM-300:
Table of Contents

Advertisement

Troubleshooting
8.3 Loading a firmware file via TFTP
5. Connect a client PC to an Ethernet port of the device via an Ethernet cable.
Note
In this state, only direct communication with the device is possible. Data traffic is not
forwarded across ports.
6. Assign an IP address to the device using DHCP or the SINEC PNI.
7. Open a Windows command prompt and change to the directory where the file with the new
firmware is located and then execute the following command :
tftp -i <IP address> put <firmware file>
Note
You can enable TFTP in Microsoft Windows as follows:
"Control Panel > Programs and Features > Turn Windows features on or off > TFTP Client".
Once the firmware has been transferred completely to the device and validated, the device
restarts. This may take a few minutes.
62
NOTICE
Risk of communication failure
Ensure that only this one Ethernet cable is connected to the switch. Plugging in multiple
Ethernet cables can cause communication failure. It does not matter which Ethernet port
you use to connect the Ethernet cable.
Product Manual, 04/2022, C79000-G8976-C585-01
SCALANCE XCM-300

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic net scalance xcm332

Table of Contents