LIMITED
WARRANTY
Instrumentation purchased new from Welch
Allyn is warranted to be free from defects in
material and workmanship under normal
use and service for a period of one year from
the date of first shipment from Welch Allyn.
This warranty shall be fulfilled by Welch
Allyn or its authorized representative repair-
ing or replacing at Welch Allyn's discretion,
any such defect, free of charge for parts and
labor.
Welch Allyn should be notified via telephone
of any defective product and the item should
be immediately returned, securely pack-
aged and postage prepaid to Welch Allyn.
Loss or damage in shipment shall be at
purchaser's risk.
Welch Allyn will not be responsible for loss
associated with the use of any Welch Allyn
product that (1) has had the serial number
defaced, (2) has been repaired by anyone
other than an authorized Welch Allyn Ser-
vice Representative, (3) has been altered,
or (4) has been used in a manner other than
in accordance with instructions.
THIS WARRANTY IS EXCLUSIVE AND IN
LIEU OF ANY IMPLIED WARRANTY OR
MERCHANTABILITY, FITNESS FOR PAR-
TICULAR PURPOSE, OR OTHER WAR-
RANTY OF QUALITY, WHETHER EX-
PRESSED OR IMPLIED, WELCH ALLYN
WILL NOT BE LIABLE FOR ANY INCIDEN-
TAL OR CONSEQUENTIAL DAMAGES.
Thermo Menu
Service Manual
7420 Carroll Road, San Diego, CA
(619) 621-6600 or (800) 854-2904
70777-000C
Model 650
Directions For Use

Advertisement

loading

Summary of Contents for Welch Allyn 650

  • Page 1 Directions For Use the date of first shipment from Welch Allyn. This warranty shall be fulfilled by Welch Allyn or its authorized representative repair- ing or replacing at Welch Allyn's discretion, any such defect, free of charge for parts and labor.
  • Page 2 1. Probe storage channel SETUP covers and insert the box into the holder on the thermometer. 2. Normal/Monitor mode 1. Unpack the Welch Allyn Ther- select switch mometer System. Check for any OPERATION damage that may have occurred 3. Display 1.
  • Page 3 continuously monitored for as long 3. Load a probe cover onto the the rectal sphincter (less for in- as necessary. fants and children). WARNING: probe. Hold the probe collar with thumb and forefinger, being care- Incorrect insertion can cause 6. After the temperature measure- ful not to hold or press the "eject"...
  • Page 4 SPECIFICATIONS • Range: 84.0°F - 108.0°F (28.9°C - 42.2°C). • Battery Capacity: Up to 1000 hours normal use. • Calibration Accuracy: +/-0.2°F (+/-0.1°C). • Dimensions: length 7 inches; width 3.7 inches; height 2.4 inches; weight 13 ounces. ERROR INDICATORS/BATTERY generally used for long term mon- REPLACEMENT itoring or when difficult situations CLEANING AND STERILIZATION...