Consistently Low Chlorine; Consistently High Chlorine - ControlOMatic MegaChlor Installation & Operation Manual

Table of Contents

Advertisement

Consistently Low Chlorine

� Power level too low: Increase the power level.
� Low salt level: Adjust the salt level as necessary. The ChlorMaker will make less chlorine with a lower
salt level.
Make sure you are measuring the chlorine at the end of a chlorine production cycle.
� Plates need cleaning: See above.
� High bather load: Additional chlorine or shock may be needed.
� Very high salt level: The
happens the ChlorMaker shuts down and will stop making chlorine to protect the power supply. Drain
out some of the water and refill with fresh water to lower the salt level. Cycle power or press the boost
button to start a production cycle to test again.
� Just doesn't keep up:
� Remove organic material such as leaves and clean the filter.
Make sure the cell is at the deepest point in the spa and in a VERTICAL ORIENTATION!
� Remove the phosphates: Phosphates are food for algae and consume chlorine. The ChlorMaker
makes chlorine slowly and removing the phosphates will help lower the spas chlorine consumption
demand.
� Shock the water: You can use either a chlorine based shock or chlorine free.

Consistently High Chlorine

� Power level too high: Lower the power level.
� Lower the salt level by adding some water.
The MegaChlor is off, No Lights
� Check if in the standby part of the cycle, watch and see if the
� The GFCI circuit breaker has tripped. Verify that there is input VAC.
� The power supply has been damaged. The rain cover didn't prevent moisture from the power supply,
was subjected to freezing weather or the cord has been cut.
CD Version - Chlorine is Always Low
The MegaChlor-CD starts a chlorine chlorine production cycle when the chlorine reaches 0 and it may be
0 for a couple hours.
� Measure the chlorine 15 minutes after a chlorine production cycle finishes. If lower than you want
increase the power level. Measuring at any other time will be a lowering measurement.
� Increase the Zero Point. The chlorine will not have to get as low for the next cycle to start.
MegaChlor Manual
RED
and
GREEN
lights may be on indicating a very high salt level. When this
www.controlomatic.com
WHITE
light flashes every 10 seconds
530-205-4520
13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MegaChlor and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Megachlor-cd

Table of Contents