DIMMER CURVE CHART
Dimmer
Ramp Effect
Standard
Stage
TV
Architectural
Theatre
POWER CORD DAISY CHAIN
With this feature you can connect the fixtures to one another using the IEC input and output sockets.
The quantity that can be connected is 20 fixtures maximum. After 20 fixtures you will need to use a new
power outlet. They must be the same fixtures. DO NOT mix fixtures.
FUSE REPLACEMENT
Disconnect the unit from its power source. Remove the power cord from the unit. Once the cord has been
removed, you will find that the fuse holder is located inside the power socket. Insert a flat-head screw driver into
the power socket and gently pry out the fuse holder. Remove the bad fuse and replace with a new one. The fuse
holder also has a holder for a spare fuse.
TROUBLE SHOOTING
A.D.J. Supply Europe B.V. – www.americandj.eu – Mega QPlus Go Instruction Manual Page 17
0S
(FadeTime)
T rise (ms)
Tdown (ms)
0
0
780
1100
1180
1520
1380
1730
1580
1940
Distance(m)
1S (FadeTime}
T rise (ms)
Tdown (ms)
0
0
1540
1660
1860
1940
2040
2120
2230
2280