tion at approx. 3% light output. Light is switched
to maximum output when movement is identified
in the detection zone. The light then returns to
basic lighting level (approx. 3%).
The period basic lighting is provided for is
matched to ambient conditions. Using basic
lighting reduces light availability. If it is not need-
ed, it is recommended to switch it OFF (P1) to
ensure lighting availability in less sunny periods.
Charging the battery manually
The red LED in the motion detector flashes if
battery capacity is too low (e.g. in poor weather).
The battery can be recharged with a standard
micro USB charging adapter (not included). Battery
recharging can take up to 6 hours.
Risk of damage to property from penetrating
moisture
When open, the micro USB charging socket (E) is
not protected from the ingress of water.
• Only recharge batteries in a dry room.
• Connect micro USB charging adapter.
– Red LED flashes: charging in progress
The LED may take up to 10 minutes to start
flashing if the battery has run down to very
low level.
– Red LED shows: battery is fully charged.
• Remove micro USB charging adapter.
– Red LED goes out.
Risk of damage to property when light is not
in use
If the light is not used for a prolonged period
(e.g. in storage), the battery may suffer irreparable
damage from exhaustive discharge.
• Set programme selector switch to P0.
• The battery must be on full charge before taking
the light out of service.
• Regularly charge the battery while the light is
not in use.
6. Malfunctions
Red LED flashing in motion detector
– Battery capacity too low.
• Charge battery with micro USB charging
adapter (not included).
Light does not switch ON
– Battery capacity too low.
• Charge battery with micro USB charging
adapter (not included).
– Open or short circuit.
• Check connections.
– Programme selector switch set to P0.
• Set programme selector switch to P1 or P2.
– Detection zone not correctly adjusted.
• Check detection zone.
Light does not switch OFF
– Continued movement within the detection zone.
• Check detection zone.
Light switches ON when it should not
– Uncontrolled movement in the detection zone:
– Wind is moving trees and bushes.
– Cars in the street being detected.
– Sudden temperature changes due to weather
(wind, rain, snow) or air expelled from fans,
open windows.
• Check detection zone.
– Light is swaying (moving) due to gusts of wind or
heavy rain.
• Mount light on a firm surface.
Battery not charging
– Solar panel dirty.
• Clean solar panel with a soft cloth and mild
detergent.
– Solar panel not installed in the best place.
• Check site of installation (as much direct
sunlight as possible).
– It may no longer be possible to recharge the
battery after many years of use.
• Get rechargeable battery changed
(replacement XSolar battery, 3.3 V 2.5 AH,
EAN 007841006488).
• Please send the product well-packed to your
nearest service station. The rechargeable
battery must only be replaced by the manu-
facturer or qualified electricians.

7. Cleaning and Maintenance

The product requires no maintenance.
Regularly checking the product for damage can
prolong its lifespan.
Removing dirt can help to make the product work
longer.
Risk of damage to property
Using the wrong detergent can damage the light.
• Make sure detergent does not harm the surface.
• Clean light with a soft cloth and mild detergent.
If solar panel is dirty or weather has left deposits
on it:
• Clean solar panel with a soft cloth and mild
detergent.