6. Service Points

6 - 1 POINT
Caution for NEUTRAL FUSING.
The fuse is in NEUTRAL line on this model. Therefore high voltage is still supplied to circuit after fuse is
blown. Always unplug the AC cord from the socket before removing Upper case and be careful not to get a
shock when checking waveforms and voltage without Upper case.
CAUTION
NEUTRAL FUSING
When Upper case is removed
Upper case is lifted as the figure with pulling a handle.
Before Replacing the LCD / Lens Prism
You should not replace separately the parts of the liquid crystal LCD / Lens Prism because it works properly only
when used together. Therefore, regarding these parts, you can either replace part , LCD / Lens Prism Ass'y, or
send the whole unit LCD / Lens Prism Ass'y back to Hitachi, where we will replace the malfunctioning part,
recondition the device and send it back to you. In that case please contact our distributor.
DISTRIBUTOR
•Do not disassemble the unit
because replacement of separate
parts is not possible.
•For repairs of the product, please
contact our distributor.
Return
– 21 –
<Without Upper case>
HITACHI
Replacement of G Panel
Handle
G Panel
Reconditioning