6. Service points

Cautions when removing the PWB Ass'y MAIN
When removing the PWB Ass'y MAIN, there is danger of damaging the connector connecting cables.
1) Disconnect 9 cables and remove 5 screws.
Take care not to touch the terminals when connecting or disconnecting the panel FPC.
Be sure to insert the panel FPC firmly. (The panel may be broken due to ratch-up).
2) Disconnect 5 cables lifting the PWB Ass'y MAIN.
Cautions when removing the UPPER CASE
UPPER CASE
16
PWB ass'y MAIN
Remove 3 screws
(3x6 with lock washer)
Disconnect 5 cables
Direction of A
HANDLE
Section A
1 : 2
Disconnect 9 cables
Remove 2 screws
(3x10 with lock washer)
Direction of B (up side)
Section A : Contact prevention
of HEXAGON NUT and RIB.
UPPER CASE is raised and
removed in the direction of B
from the HANDLE side, pulling a
HANDLE in the direction of A.
HEXAGON NUT
Section A
1 : 1
RIB