Page 1
IP110 DIESEL INDIRECT FIRED SPACE HEATER NOT FOR DOMESTIC USE-SPACE HEATING ONLY MADE IN ITALY SPITWATER AUSTRALIA PTY LTD 953 METRY STREET NORTH ALBURY NSW 2640 AUSTRALIA WARNING: Read and understand this instruction manual before operating this unit and retain for future reference.
Page 2
INTRODUCTION Spitwater Australia is proudly Australian owned and operated since 1983. Our promise is to provide our customers with superior quality portable industrial heaters built to the highest of standards that will see many years of reliable service. The JETFIRE range of portable industrial heaters are designed to give safe, efficient and reliable service when the correct operating and safety instructions are followed, and proper attention is given to all required maintenance procedures in order to maintain the unit in peak operating condition.
IP 110 TECHNICAL SPECIFICATIONS II S Combustion Indirect [kW] 75.06 110.02 [kcal/h] 64553 94616 Max heating output [kW] 80.00 117.26 [BTU/h] 275214 403387 [kW] 66.80 99.02 [kcal/h] 57452 85155 Net heating output [kW] 71.20 105.54 [BTU/h] 244941 363048 Air output 5500 Fuel consumption [kg/h]...
Page 4
OPERATING DIAGRAM 16 CONTROL LAMP 1 COMBUSTION CHAMBER 6 FAN MOTOR 11 WHEEL 17 POWER CORD 12 FUEL TANK 2 BURNER 7 FAN 18 HIGH-LOW THERMAL POWER SWITCH 13 RESET BUTTON WITH CONTROL LAMP 3 NOZZLE 8 FUEL FILTER 19 BURNER MOTOR 14 MAIN SWITCH 4 SOLENOID VALVE 9 FUEL CIRCUIT...
IP110 IMPORTANT Before using the space heater, carefully read all of the instructions and follow them scrupulously. The manufacturer cannot be held responsible for damage to persons and/or property caused by improper use of the equipment. This instruction manual is an integral part of the equipment and must therefore be stored carefully and passed on with the unit in the event of a change of ownership.
IP110 different colours (Self-diagnosis light) To select the heating power level, turn the depending on the type of safety that tripped: switch (18) to the position corresponding to the • Flashing orange: false flame detected during first stage (I S) or second stage (II S). restart cycle.
Every 50 hours maintenance (qualified Spitwater service technician to carry out) The heater can be supplied in a mobile version • Remove top cover and clean the motor, fan...
Page 8
IP110 • Check fuel pressure setting of fuel pump • Inspect and test the burner.
Page 10
IP110 INSTALLATION GUIDE RECOMMENDED CHIMNEY LAY-OUT DESCRIPTION A) Minimum 1 m B) Minimum 1 m C) As short as possible D) Greater than or equal to diameter of heater smoke outlet E) Minimum 1 m 1) Anti-wind device provided with heater 2) Horizontal crossing with 5°...
Defective electrical Contact authorised Spitwater service agent motor bearings Burned out condenser Contact authorised Spitwater service agent Defective electric ignitor Contact authorised Spitwater service agent Fan stops during Flashing Steady red start-up or heating red or Defective flame control...
IP110 WIRING DIAGRAM AP CONTROL BOX PHOTOCELL ROOM THERMOSTAT PLUG MV FAN MOTOR ELECTRIC PILOT LAMP FUA FUSE FUSE CONTROL SWITCH LI1 OVERHEAT THERMOSTAT EV2 SOLENOID VALVE II° Stage EV1 SOLENOID VALVE I° Stage ANTI-JAMMING FILTER MB BURNER MOTOR PLUG OF PRE-HEATED FILTER HIGH –...