OPERATING AND MAINTENANCE
 
 
 
MADE IN ITALY
FOR
SPITWATER AUSTRALIA PTY LTD
953 METRY STREET
NORTH ALBURY NSW 2640
AUSTRALIA
WARNING: Read and understand this instruction manual before operating this
unit and retain for future reference.
Failure to follow operating, safety and maintenance instructions outlined in this
manual releases the manufacturer from any responsibility for any accidents or
damage incurred and may render any warranty void.
 
 
ORIGINAL INSTRUCTIONS
MANUAL
DP65 / DP105
DIESEL DIRECT FIRED
SPACE HEATER
NOT FOR DOMESTIC USE-SPACE HEATING ONLY
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JETFIRE DP65 and is the answer not in the manual?

Questions and answers

Summary of Contents for Spitwater JETFIRE DP65

  • Page 1       NOT FOR DOMESTIC USE-SPACE HEATING ONLY     MADE IN ITALY   SPITWATER AUSTRALIA PTY LTD 953 METRY STREET   NORTH ALBURY NSW 2640 AUSTRALIA     WARNING: Read and understand this instruction manual before operating this unit and retain for future reference.
  • Page 2 BLANK     2   ...
  • Page 3 GENERAL DESCRIPTION & INTENDED USE   Spitwater has an extensive range of spare parts and accessories to suit all your heating needs. For spare parts, accessories and service please contact 1800 SPITWATER (1800 774 892) and to view Spitwater’s extensive range of Jetfire industrial heaters online visit www.spitwater.com.au...
  • Page 4 BLANK     4   ...
  • Page 5: Technical Specifications

      TECHNICAL SPECIFICATIONS DP 65 DP 105 Combustion Direct Direct [kW] 65.0 105.0 [kcal/h] 55,885 90,252 Max heating output [kW] 69.3 111.1 [BTU/h] 237,067 380,331 [kW] - - - - - - [kcal/h] - - - - - - Net heating output [kW] - - - - - -...
  • Page 6 OPERATING DIAGRAM 1 COMBUSTION CHAMBER 6 MOTOR 11 WHEEL 16 CONTROL LAMP 7 FAN 17 POWER CORD 2 BURNER 12 FUEL TANK 3 NOZZLE 8 FUEL FILTER 13 RESET BUTTON OF THE ELECTRONIC EQUIPMENT 18 INPUT VOLTAGE SWITCH 4 SOLENOID VALVE 9 FUEL CIRCUIT 14 MAIN SWITCH 19 OUTLET CONE...
  • Page 7: General Recommendations

    DP65 / DP105 IMPORTANT Before using the space heater, carefully read all of the instructions and follow them scrupulously. The manufacturer cannot be held responsible for damage to persons and/or property caused by improper use of the equipment. This instruction manual is an integral part of the equipment and must therefore be stored carefully and passed on with the unit in the event of a change of ownership.
  • Page 8: Operation

    DP65 / DP105 The generator can only work automatically Warning when a control device, such as, for example, a NEVER do more than two restarts in thermostat or a timer, is connected to the a row: uncombusted diesel fuel may heater.
  • Page 9: Maintenance

    Warning Before moving the heater: Every 50 hours maintenance (qualified • Stop the heater as indicated in the Spitwater service technician to carry out) “STOP” paragraph;  Remove top cover and clean the motor, fan • Cut electrical power by removing blade and the interior shell the plug from the electrical socket;...
  • Page 10 DP65 / DP105   ASSEMBLY INSTRUCTIONS 10   ...
  • Page 11 DP65 / DP105   11   ...
  • Page 12 DP65 / DP105   INSTALLATION GUIDE RECOMMENDED CHIMNEY LAY-OUT                       DESCRIPTION A) Minimum 1 m B) Minimum 1 m C) As short as possible D) Greater than or equal to diameter of heater smoke outlet E) Minimum 1 m 1) Anti-wind device provided with heater 2) Horizontal crossing with 5°...
  • Page 13: Troubleshooting

    Excess fuel at Contact authorised Spitwater service agent burner Steady Defective solenoid Heater does not stop Contact authorised Spitwater service agent green seal If the heater is still not working properly, please contact your nearest authorise Spitwater agent 13   ...
  • Page 14 DP65 / DP105   14   ...
  • Page 15: Wiring Diagram

    DP65 / DP105   WIRING DIAGRAM                                            AP CONTROL BOX PHOTOCELL   ROOM THERMOSTAT PLUG CO CAPACITOR   ELECTRIC PILOT MV FAN MOTOR LI1 OVERHEAT THERMOSTAT FUA FUSE...
  • Page 16 DP65 / DP105   16   ...