Malfunction
"E:35 / -10"
flashes.
burns.
flashes.
All other error codes.
"E:30/-20"
Cause and Troubleshooting
Close the tap.
Please contact customer service.
†Customer Service", page 49
The Voltage Control System detects an impermissible
voltage drop.
No solution possible.
Remark:When the supply voltage has stabilized, the
program continues normally.
Undervoltage can cause a program extension.
No solution possible.
Temperature is too high.
Wait for the temperature to drop.
→ †program cancel", Page 33
Water level is too high.
Select a suitable program for draining.
→ †Programs", Page 26
Door is not closed.
Close the door.
1.
To start the program, pressStart/Refill.
2.
Laundry is wedged in the door.
Open the door again.
1.
Remove trapped laundry.
2.
Close the door.
3.
To start the program, pressStart/Refill.
4.
Malfunction
Please contact customer service.
†Customer Service", page 49
Solenoid valve defective.
Please contact customer service.
†Customer Service", page 49
Detergent dosage is too high.
Reduce the amount of detergent for the next wash
with an equal load.
Additional water filled.
▶ Do not fill the device with additional water during
operation.