KX-TG2344B / KX-TGA234B
15.4. Reset Circuit
Function:
This circuit is used to initialize the microcomputer when it incorporates an AC adaptor.
Circuit Operation:
When the AC Adaptor is inserted into the unit, then the voltage is shifted by IC300 and power is supplied to the DSP.
The set starts to operate when VCC goes up to 3.3V or more in the circuit voltage diagram.