CHARACTERISTICS
After inserting the battery pack into the charger, the battery
is automatically charged (red control lamp is illuminated
continuously).
When a hot or cold battery pack is inserted into the charger
(fl ashing red lamp), charging begins automatically once the
battery reaches the correct charging temperature (+5 °C –
+40 °C). The maximum charging current is fl owing when the
temperature of the li-ion-battery is between +5 °C and +40 °C.
The battery charging time is between 1 - 20 minutes (at 1.5
Ah), depending on the state of discharge.
When the battery is fully charged, the LED on the charger
changes from red to green.
Recharge the battery pack when convenient for you and your
job. MILWAUKEE batteries do not develop a memory when
charged after only a partial discharge. It is not necessary to run
down the battery pack before charging it.
As a general practice, it is best to unplug battery chargers and
remove batteries when not in use. No battery pack damage will
occur if the charger and battery pack are left plugged in.
If both LEDs fl ash alternately, the rechargeable battery is either
not fully installed or there is a fault with the battery or charger.
Take the charger and battery out of use immediately for
safety reasons, and have them inspected by a MILWAUKEE
customer service centre.
The charger can charge two battery packs at the same time.

LIGHT INDICATORS

Continuous red
Slow fl ashing
green
Continuous green
Fast fl ashing red
Flashing red/
green

TRANSPORTING LITHIUM BATTERIES

Lithium-ion batteries are subject to the Dangerous Goods
Legislation requirements.
Transportation of those batteries must be done in accordance
with
local,
national,
and
regulations.
Batteries can be transported by road without further
requirements.
Commercial transport of lithium-ion batteries by third parties
is subject to Dangerous Goods regulations. Transport
preparation and transport are exclusively to be carried out
Charging
Approaching full charge
Charging is complete
Battery is too hot or too cold
- charging begins when the
battery reaches the correct
charging temperature.
Damaged or faulty battery
pack
international
provisions
and
by appropriately trained persons, and the process must be
accompanied by corresponding experts.
When transporting batteries:
Ensure that battery contact terminals are protected and
insulated to prevent short circuit.
Ensure that the battery pack is secured against movement
within packaging.
Do not transport batteries that are cracked or leaking.
Check with the forwarding company for further advice.

MAINTENANCE

If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualifi ed persons in
order to avoid a hazards.
Use only MILWAUKEE accessories and spare parts. Should
components that have not been described need to be replaced,
contact one of our MILWAUKEE service agents (see our list of
guarantee/service addresses).
If needed, an exploded view of the product can be ordered.
State the product type and the serial number on the label, and
order the drawing at your local service centres.
SYMBOLS
Read the instructions carefully before starting
the product.
Do not burn used battery packs.
Never charge a damaged battery pack.
Replace the battery pack with a new one.
Do not dispose of electric tools, batteries/
rechargeable batteries together with household
waste material.
Electric tools and batteries that have reached
the end of their life must be collected separately
and returned to an environmentally compatible
recycling facility.
Check with your local authority or retailer for
recycling advice and collection point.
The product is only suitable for indoor use.
Never expose the product to rain.
Time-lag fuse 5 A