System Specifications

4. Insert the new filter into position.
5. Replace the cover, and fasten the clips.

Disposing of the Filters

The combined filter is manufactured from non-toxic materials. Filters are not re-usable. The
method of disposal of the used filters depends on the material deposited on them.
It is the customer's responsibility to verify that the disposal of filters complies with all local
and/or industrial regulations.
System Specifications
Capacity: 75 m³/h (44CFM)
Weight: 10.5 kg (23.1 lbs)
Fan type: Centrifugal
Power: 100 W
Voltage: 100-230 VAC
Frequency: 50/60 Hz
Full Load Current: 2.0 A
Noise Level: Below 57 dBA (at typical operating speed)
Overvoltage category: II
Maximum altitude: 2000 m (6561 ft.)
Allowable voltage input: +/-10%
Control cable: 22-48 VDC input, 20 mA

Dimensions

Do not activate the system without a filter.
Height
Depth
Width
© Copyright 2020 Stratasys. All rights reserved.
Metric (mm)
Imperial (inches)
413
16.3
298
11.7
283
11.1
Disposing of the Filters