Victron energy VBC-HV Manual page 11

Ve.net battery controller
Table of Contents

Advertisement

3.3
Historic data
The VBC-HV will keep track of historical data to enable you to get more
information about the state and the past use of the batteries.
Where to find the "Historical data" menu
3.3.1
Battery Monitor
157V
-0.5A
Battery voltage
157.40V
Historic data
[Press enter]
3.3.2
Historical data explained
Name
Deepest
The deepest discharge in Ah.
discharge
Depth last disch.
The depth of the last discharge in Ah. This value will be reset to 0
when the State of Charge reaches 100% again.
Average
The average discharge over all the cycles counted
discharge
Number of cycles
Every time the battery is discharged below 65% of its rated
capacity and charged back to at least 90%, one cycle is counted.
Full discharges
The number of times the battery has been discharged to a 0%
state of charge.
Cumulative Ah
Records the total energy consumed over all charge cycles.
Last full charge
The time that has elapsed since the battery was last fully charged.
Maximum voltage
Maximum measured voltage. Can be used to check for faulty
chargers and alternators.
Minimum voltage
Lowest measured voltage. Can be used to check if the batteries
have been excessively discharged.
Step 1) Press "Enter" to enter the VBC-HV
99%
Step 2) Press "▼" to scroll through the
Step 3) Press "Enter" to enter the "Historic
Historic data
Description
menu.
menu until you see „Historic data".
data" menu
Unit
Amp hours.
Amp hours.
Amp hours.
Amp hours.
Days.
Volts.
Volts.
7

Advertisement

Table of Contents
loading