Troubleshoot ng

5.2 Troubleshoot ng
When troubles occur, please check the follow ng po nts before contact ng a repa r company.
Problem
Poor cool ng
performance
The un t s not
work ng
22 / 28 EN
Poss ble causes
Temperature sett ng may be
h gher than amb ent room
temperature
The heat exchanger on the ndoor
or outdoor un t s d rty
The a r f lter s d rty
The a r nlet or outlet of e ther un t
s blocked
Doors and w ndows are open
Excess ve heat s generated by
sunl ght
Too many sources of heat n
the room (people, computers,
electron cs, etc.)
Low refr gerant due to leak or
long-term use
SILENCE funct on s
act vated(opt onal funct on)
Power fa lure
The power s turned off
The fuse s burned out
Remote control batter es are dead Replace batter es
The Un t's 3-m nute protect on
has been act vated
T mer s act vated
solut on
Lower the temperature sett ng
Clean the affected heat exchanger
Remove the f lter and clean t
accord ng to nstruct ons
Turn the un t off, remove the
obstruct on and turn t back on
Make sure that all doors and
w ndows are closed wh le
operat ng the un t
Close w ndows and curta ns dur ng
per ods of h gh heat or br ght
sunsh ne
Reduce amount of heat sources
Check for leaks, re-seal f
necessary and top off refr gerant
SILENCE funct on can lower
product performance by reduc ng
operat ng frequency. Turn off
SILENCE funct on.
Wa t for the power to be restored
Turn on the power
Replace the fuse
Wa t three m nutes after
restart ng the un t
Turn t mer off
Spl t-type room a r cond t oner / User Manual