Download Print this page

Maytag MGDE200X User Manual

Clothes dryer

Advertisement

Quick Links

DRYER DIMENSIONS
Front view:
27"
(686 mm)
/
35
3
"
8
(899 mm)
1"
(25 mm)
Back view:
Electric
14"
(358 mm)
NOTE: Most installations require a minimum
5" (102 mm) clearance behind the dryer for
the exhaust vent with elbow. See "Venting
Requirements".
Custom under counter installation (dryer only):
1"
(25 mm)
NOTE: Some models not recommended for
undercounter installation.
PRODUCT MODEL NUMBERS
MGDE201Y, MGDE200X, MGDE250X,
MGDE251Y, MGDE301Y
Side view:
Closet Installation (stacked washer and dryer):
/
6
1
"
4
(159 mm)
/
28
"
1
8
(715 mm)
/
/
5
1
"
3
1
"
2
2
(140 mm)
(89 mm)
(25 mm)
Cabinet installation (dryer only):
7"
(178 mm)
39" min.
(990 mm)
1"
4"
(25 mm)
(102 mm)

Gas Dryer

29"
(736 mm)
Left or
right side
exhaust
/
3
1
"
2
(89 mm)
/
1
5
"
8
(41 mm)
/
6
7
"
8
(174 mm)
6"
(152 mm)
3"
(76 mm)
71"
(310 cm
(1803 mm)
(155 cm
3"
(76 mm)
1"
1"
(25 mm)
18"
(460 mm)
(25 mm)
1"
(25 mm)
Door open view:
47
/
1
8
(1197 mm)
Closet installation (dryer only):
34" recommended
48 in.
2
)
2
24 in.
2
)
2
4"
(102 mm)
(25 mm)
Spacing for recessed area or closet
installation
All dimensions show recommended spacing
allowed, with tested spacing of 0" (0 mm)
clearance on sides and rear.
■ Additional spacing should be considered
for ease of installation and servicing.
■ Additional clearances might be required
for wall, door, and floor moldings.
■ Additional spacing should be considered
on all sides of the dryer to reduce noise
transfer.
■ For closet installation, with a door,
minimum ventilation openings in the top
and bottom of the door are required.
Louvered doors with equivalent
ventilitation openings are acceptable.
■ Companion appliance spacing should
also be considered.
■ No other fuel-burning appliance may be
1"
installed in the same
closet as the dryer.
48
/
"
1
8
(1238 mm)
"
3"
(76 mm)
(864 mm)
48 in.
2
(310 cm
)
2
18" min.
(457 mm)
24 in.
2
(155 cm
)
2
3"
(76 mm)
1"
(25 mm)
1"
W10443045B
02/2012

Advertisement

loading

Summary of Contents for Maytag MGDE200X

  • Page 1: Gas Dryer

    (990 mm) 1" (25 mm) 1" (25 mm) NOTE: Some models not recommended for undercounter installation. Gas Dryer PRODUCT MODEL NUMBERS MGDE201Y, MGDE200X, MGDE250X, MGDE251Y, MGDE301Y Side view: 29" (736 mm) Left or right side exhaust (89 mm) (41 mm) "...
  • Page 2: Installation Requirements

    INSTALLATION REQUIREMENTS GAS SUPPLY REQUIREMENTS Gas supply This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used.

This manual is also suitable for:

Mgde250xMgde201yMgde251yMgde301y