QUALITY LIFTS Q12 Installation, Operation & Maintenance Manual page 3

Two post surface mounted lift
Table of Contents

Advertisement

V
C
ERTICAL
LEARANCE
Check the height of the area where the lift is to
be installed. Clearance should be calculated
based on the full raised height of the lift.
Failure by purchaser to
provide
WARNING
clearance could result in
unsatisfactory
lift
damage, or personal injury.
F
LOORING
Be certain you have the proper concrete floor to
properly handle the loaded lift. Floor should be in
generally good condition with no large cracks,
spalling or deterioration.
Minimum requirements for concrete are 4
inches
minimum
reinforcement, 3500 psi, cured for 28 days per
local commercial practice. Floor should be
level within 3/8 inch over the installation area. No
anchors should be installed within 8 inches of any
crack, edge, or
expansion joint. If
conditions cannot be met, a pad may be poured
to accommodate the lift.
Check with local building inspectors and/or
permits office for any special instructions or
approvals required for your installation.
Failure by purchaser to
provide the recommended
WARNING
mounting surface could
result in unsatisfactory lift performance,
property damage, or personal injury.
L
OCATION
This lift has been evaluated for indoor use only
with an operating ambient temp. range of 5 –
40°C (41– 104°F)
E
R
LECTRICAL
EQUIREMENTS
For lift installation and operation for single phase
units, it is necessary to have a dedicated circuit
with a double pole 25 amp circuit breaker or time
delay fuse.
S
N
AFETY
OTICES AND
For your safety, and the safety of others, read
and understand all of the safety notices and
decals included here.
R
EAD ENTIRE MANUAL BEFORE
,
ASSEMBLING
INSTALLING
,
OPERATING
OR SERVICING THIS
.
EQUIPMENT
P
ROPER MAINTENANCE AND
INSPECTION IS NECESSARY FOR SAFE
.
OPERATION
DO NOT
OPERATE A DAMAGED LIFT
Model Q12
Installation, Operation and Maintenance
adequate
performance,
property
depth,
with
steel
these
D
ECALS
,
.
Page 3
Safety decals similar to those shown here are
found on a properly installed lift. Be sure that all
safety decals have been correctly installed on the
Power Unit reservoir. Verify that all authorized
operators know the location of these decals and
fully understand their meaning. Replace worn,
faded, or damaged decals promptly.
Do not attempt to raise a
WARNING
vehicle on the lift until the
lift
installed and adjusted as described in this
manual.
has
been
correctly
Rev. 02/01/15