Quark-elec Manual
2. Select 'Network'
3. Choose the Protocol: TCP
4. Insert IP address. In Ad-hoc
mode this is 192.168.1.100. In
Station mode this will be a
different IP address.
5. Input the Dataport: 2000
6. Click 'Apply' and then 'OK'
Protocol
TCP
IP
192.168.1.100
address
This is the IP
address for Ad-hoc
WiFi. In Station
mode, simply
replace with the
relevant IP (See
Station mode.).
Data Port
2000
11. Updating/ upgrading Firmware
From time to time, Quark-elec provides new firmware updates to support additional NMEA 2000 PGNs
and NMEA 0183 messages. Users can update the firmware on their devices to the latest available
version.
The firmware can be upgraded through the following process:
1. Power OFF the A032 (Disconnect it from NMEA 2000 network).
2. Connect the NMEA 0183 NMEA IN – (black) and NMEA 0183 NMEA OUT – (blue) wires.
Ensure the correct cables are connected before continuing.
3. Connect NMEA 0183 NMEA IN + (Gray) and NMEA 0183 NMEA OUT + (White) wires.
Ensure the correct cables are connected before continuing.