Download Print this page
Zamel CTG-01 Manual

Zamel CTG-01 Manual

Carbon monoxide sensor

Advertisement

Quick Links

1. ZAMEL Sp. z o. o. assures a 24 month guarantee for the product.
warranty card
2. The manufacturer's guarantee does not cover any of the following actions:
a) mechanical damage during transport, loading / unloading or under other circumstances,
There is a 24 month guarantee
on the product.
b) damage caused by incorrect product mounting or misuse,
c) damage caused by unauthorised modifications made by the PURCHASER or any third parties to the product or any other
devices required for the product functioning,
d) damage caused by Act of God or any other incidents independent of the manufacturer – ZAMEL Sp. z o. o.
e) power supply sources (batteries) included in the device when sold (if included).
3. The PURCHASER shall lay any claims in writing in the place of purchase or to ZAMEL Sp. z o. o.
4. ZAMEL Sp. z o. o. is liable for processing any claim according to current Polish legislation.
5. ZAMEL Sp. z o. o. shall process the claim at its own discretion: product repair, replacement or money return.
6. The manufacturer's guarantee is valid in the Republic of Poland.
7. The PURCHASER's statutory rights in any applicable legislation whether against the retailer arising from the purchase
contract or otherwise are not affected by this warranty.
Salesman stamp and signature,
date of sale
ZAMEL Sp. z o.o.
43-200 Pszczyna, ul. Zielona 27, tel.: (32) 210 46 65; fax: (32) 210 80 04
e-mail: marketing@zamel.pl, www.zamel.com
CARBON MONOXIDE SENSOR CTG-01
Carbon monoxide, commonly referred to coal smoke, is a highly toxic, colourless and odourless gas easily spreading in the air. Since this gas is colourless and
odourless, it is highly important to detect early a dangerous concentration of coal smoke in a room we usually stay in, as it endangers our health and life. Natural
gas used e.g. in a gas stove is a colourless gas with a faint odour. It is lighter than air and therefore it accumulates in the upper parts of rooms. Gas combined
with oxygen forms a highly explosive mixture. Propane-butane (LPG) gas is, in turn, heavier than air and similarly to the natural gas is an explosive mixture
when combined with oxygen. CTG-01 sensor is used to monitor continuously the dangerous concentration of both carbon monoxide and natural gas as well as
propane-butane in the air.
Features:
• semiconductor and electrochemical sensor
• LCD screen showing current level of carbon monoxide fumes during an alarm
• power supply voltage 230 V AC
• additional battery back-up (9 V battery) in case of power decay
• alarm optical and sound signalling (85dB)
• sensor failure signalling (auto-diagnostic system)
• carbon monoxide detection (in accordance with reference standards PN-EN 50291 1:2010+A1:2012):
- 50 ppm (in less than 90 minutes)
- 100 ppm (in less than 40 minutes)
- 300 ppm (in less than 3 minutes)
• alarm level of gas detection: 10 % LEL
Before sensor mounting, first read the manual instruction included in the packaging.
Basic power supply voltage: 230 V AC
Back-up power supply: 9 V DC
(1 x battery, type 6F22) IP20
Product net weight: 0.237 kg
Country of origin: PRC
Made for: Zamel Sp. z o.o. by: SCI Ltd.
Declaration of Conformity is at www.zamel.com
CTG-01 EN.indd 2-3
Tested
in a specialized
chamber
Efficiency certificate
The symbol means selective collecting of
electrical and electronic equipment.
It is forbidden to put the used equipment
together with other waste.
CARBON MONOXIDE SENSOR
CTG-01
Tested
in a specialized
chamber
Efficiency certificate
www.zamel.com
05.01.2017 13:13

Advertisement

loading

Summary of Contents for Zamel CTG-01

  • Page 1 Propane-butane (LPG) gas is, in turn, heavier than air and similarly to the natural gas is an explosive mixture when combined with oxygen. CTG-01 sensor is used to monitor continuously the dangerous concentration of both carbon monoxide and natural gas as well as propane-butane in the air.
  • Page 2 Longer device operation based on battery back-up is not recommended as it can discharge the battery quickly. The mains power supply (230 V AC) connection should be constant. In case battery exchange is required, the device activates short alarm sound signals every 10 seconds (sound + LED red “ALARM” optical signalling). CTG-01 EN.indd 4-5 05.01.2017 13:13...