8-5-6. Only outdoor fan does not operate
Shut off the power supply
from AC outlet once and
turn it on after 5 seconds.
Does the OPERATION lamp blink?
YES
Does the power turn on by
pushing the [
] button
of the remote control?
YES
Is the voltage across the indoor 
1
2
terminal (
 -
 AC 220-240V?
YES
Is cable connection between indoor 
and outdoor units correct?
YES
Is the voltage across the outdoor 
1  - 2 )
terminal
(
 AC 220-240V?
YES
 Are all the cords for outdoor 
fan motor normal?
YES
Is the outdoor fan motor winding normal?
(Check the winding resistance)
YES
Is the capacitor for compressor normal?
YES
Outdoor fan motor is defective.
NO
NO
NO
)
NO
NO
NO
NO
NO
See "Power can not be turned on ".
See "Power can not be turned on ".
Relays (RY01) or IC31
or IC30 is failure.
Correct cabling between indoor 
and outdoor units.
Cables between indoor 
and outdoor units are defective.
Correct the wire or 
replace the defective cords.
Outdoor fan motor is defective.
Capacitor for outdoor 
fan motor is defective.
 –    3 5  – 
FILE NO. SVM-0 5039
Replace the
P.C. board.