Setting

11 Setting
This chapter explains how to change and set the driver functions using the switches on the front face of the driver.
Note
Before operating any switch, turn off the driver power and wait for the POWER LED to turn off.

11.1 Resolution

Use the resolution switches (SW1-No.3/No.4) to set a desired resolution per revolution of the motor output shaft.
OFF
OFF
Note
• The new settings of the resolution switches will become effective after the power is cycled.
• When changing the resolution using the CS input, use the switches in "No.3: OFF"/"No.4:
OFF" or "No.3: OFF"/"No.4: ON" combination. If the CS input is turned ON when "No.3: ON" is
selected, the resolution will not be changed.
• To change the basic resolution setting: Refer to page 43.

11.2 Pulse input mode

Set a desired pulse input mode of the driver according to the pulse output mode of the controller
(pulse generator) used with the driver. Set a desired mode using the pulse input mode select
switch (SW1-No.1).
OFF: 2-pulse input mode (when the CW input and CCW input are used)
ON: 1-pulse input mode (when the PLS input and DIR input are used)
Note
• The new setting of the pulse input mode select switch will become effective after the power is
cycled.
• The factory setting of the pulse input mode depends on the destination country.
• To change the basic setting for pulse input mode: Refer to page 44.
−40−
ON
OFF
ON
OFF
Resolution 1000 P/R
OFF
ON
Resolution 10000 P/R Resolution 5000 P/R
Current setting switch (Factory setting: F)
Speed filter setting switch (Factory setting: 1)
Resolution switch (Factory setting: OFF)
Keep this switch in the OFF position.
Pulse input mode select switch
ON
OFF
Resolution 500 P/R
ON
ON
2P
1P