TABLE OF CONTENTS

Technical Data....................................................... 2
Initial Pump Start Up Information........................... 2
Pre-Installation Cleaning........................................ 3
Location and Piping ............................................... 3
Check Valves......................................................... 3
Pump Mounting...................................................... 3
Motor Installation ................................................... 4
Pre-Start Up Check List ......................................... 5
Start Up Procedures .............................................. 5
Pump Rotation ....................................................... 5
Reverse Rotation ................................................... 5
Flushing the Pump................................................. 5
Pump Relief Valve ................................................. 6
Relief Valve Setting and Adjustment ..................... 6
Strainers ................................................................ 7
Lubrication ............................................................. 7
Vane Replacement ................................................ 8
Pump Disassembly ................................................ 8
Pump Assembly..................................................... 9
TROUBLE SHOOTING ......................................
NOTE: Numbers in parentheses following individual parts
indicate reference numbers on Blackmer Parts Lists 108-
A01 and 108-A02
NOTE: Blackmer pump manuals & parts lists may be
obtained from Blackmer's website (www. blackmer. com)
or by contacting Blackmer Customer Service
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the product, or in the manual,
look for one of the following signal words and be alert to the
potential for personal injury, death or major property damage
Warns of hazards that WILL cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause serious personal injury,
Page
death or major property damage.
Warns of hazards that CAN cause personal injury
Indicates special instructions which are very
important and must be followed.
Blackmer Seal-Less pumps MUST only be installed In
systems, which have been designed by qualified
engineering personnel. The system MUST conform to
all applicable local and national regulations and
safety standards.
This manual is intended to assist in the installation
and operation of the Blackmer Seal-Less pumps, and
MUST be kept with the pump.
Blackmer Seal-Less pump service shall be performed
by qualified technicians ONLY. Service shall conform
to all applicable local and national regulations and
11
safety standards.
Thoroughly review this manual, all instructions and
hazard warnings, BEFORE performing any work on
the Blackmer Seal-Less pumps.
Maintain ALL system and Blackmer Seal-Less pump
operation and hazard warning decals.
960901
INSTRUCTIONS NO. 108-A00_apr05
Section
108
Effective
April 2005
Replaces
July 2002
SAFETY DATA
or property damage.
NOTICE:
NOTICE:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMVP15B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PSG Dover SMVP15B

  • Page 1: Table Of Contents

    BLACKMER SEAL-LESS PUMPS INSTRUCTIONS NO. 108-A00_apr05 Section INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS Effective April 2005 MODELS: SMVP15B, SMVP30B Replaces July 2002 Discontinued models: MVP15B, 20B, 30B SAFETY DATA This is a SAFETY ALERT SYMBOL. When you see this symbol on the product, or in the manual,...
  • Page 2: Pump Data

    SAFETY DATA IF PUMPING HAZARDOUS FLUIDS, DISCONNECTING FLUID OR PRESSURE SYSTEM MUST BE FLUSHED, PRIOR TO CONTAINMENT COMPONENTS DURING PERFORMING SERVICE OR PUMP OPERATION CAN CAUSE MAINTENANCE SERIOUS PERSONAL INJURY, DEATH Hazardous or toxic Hazardous pressure OR MAJOR PROPERTY DAMAGE fluids can cause can cause personal serious injury.
  • Page 3: Installation

    INSTALLATION NOTICE: Check alignment of pipes to pump to avoid strains which BLACKMER SEAL-LESS PUMPS MUST ONLY BE might later cause misalignment. See Figure 1. Unbolt INSTALLED IN SYSTEMS DESIGNED BY QUALIFIED flanges or break union joints. Pipes should not spring ENGINEERING PERSONNEL.
  • Page 4: Motor Installation

    INSTALLATION MOTOR INSTALLATION STRONG MAGNETIC FIELD CAN CAUSE PERSONAL INJURY OR DEATH TO INDIVIDUALS WITH MEDICAL IMPLANTS OR OTHER MAGNETIC FIELD SENSITIVE MEDICAL Strong CONDITIONS Magnetic field FAILURE TO USE CARE WHEN HANDLING MAGNETS CAN CAUSE Figure 3 PERSONAL INJURY Strong magnetic field can cause Dim “A”...
  • Page 5: Operation

    OPERATION If possible, check the flow rate to ensure the pump is operating within expected parameters. Inspect piping, fittings and associated system equipment OPERATION WITHOUT COUPLING for leaks, noise, vibration and overheating. GUARD CAN CAUSE SERIOUS PERSONAL INJURY, DEATH OR MAJOR If equipped, check the pressure relief setting of the pump PROPERTY DAMAGE relief valve by gradually closing a valve in the discharge...
  • Page 6: Pump Relief Valve

    PROTECT THE PUMP FROM EXCESSIVE PRESSURE. setting. The SMVP15B and SMVP30B pump models are offered with DO NOT remove the R /V Cap OR adjust the relief valve an optional pump relief valve assembly that bolts onto the pressure setting while the pump is in operation.
  • Page 7: Maintenance

    MAINTENANCE FAILURE TO DISCONNECT AND OPERATION WITHOUT GUARDS IN LOCKOUT ELECTRICAL POWER PLACE CAN CAUSE SERIOUS BEFORE ATTEMPTING MAINTENANCE PERSONAL INJURY, MAJOR CAN CAUSE SHOCK, BURNS OR PROPERTY DAMAGE, OR DEATH. DEATH Hazardous voltage. Do not operate Can shock, burn or without guard cause death.
  • Page 8: Vane Replacement

    MAINTENANCE VANE REPLACEMENT Drain the pump and system, as required. Drain plugs (73A) are located at the base of the cylinder of SMVP Models. FAILURE TO USE CARE WHEN For replacement of the vanes ONLY, remove the outboard HANDLING MAGNETS CAN CAUSE head, following steps 10 and 11 in the "Pump PERSONAL INJURY Disassembly"...
  • Page 9: Pump Assembly

    MAINTENANCE MAGNET HOUSING DISASSEMBLY Remove the four housing/adapter capscrews (54B), and pull the motor, motor adapter (86) and outer magnet (53) from the magnet housing (57). Remove the motor adapter capscrews (56), and the motor adapter (86) from the motor. Place a flat wrench or “plate”...
  • Page 10 MAINTENANCE RELIEF VALVE ASSEMBLY (If Equipped) 5. Install the outboard head and bearing assembly (23) on the pump cylinder with the V-notch down, towards the Insert the valve (9) into the relief valve bore of the casing bottom of the cylinder. Use the head dowel pins for proper with the fluted end inward.
  • Page 11: Troubleshooting

    TROUBLESHOOTING NOTICE: MAINTENANCE SHALL BE PERFORMED BY QUALIFIED TECHNICIANS ONLY, FOLLOWING THE APPROPRIATE PROCEDURES AND WARNINGS AS PRESENTED IN THIS MANUAL. PROBLEM CAUSE Suction/discharge valve incorrectly set. Pump Not Priming Leaks in suction piping. See causes 1 through 7 Incorrect rotation. Broken shaft.