Download Print this page

PSG Dover Mouvex AF TM H Series Installation Operation & Maintenance

Advertisement

Quick Links

TM Series pumps are covered 24 months by warranty within the limits mentioned in our General Sales Conditions.
In case of a use other than that mentioned in the Instructions manual, and without preliminary agreement of MOUVEX,
warranty will be canceled.
Z.I. La Plaine des Isles - F 89000 AUXERRE - FRANCE
Tel. : +33 (0)3.86.49.86.30 - Fax : +33 (0)3.86.49.87.17
contact@mouvex.com - www.mouvex.com
Pump AF TM H
WARRANTY :
INSTRUCTIONS 1005-C00 e
Section
1005
Effective
September 2018
Replaces
December 2012
Translation of the
original instructions
INSTALLATION
OPERATION
MAINTENANCE
Your distributor :

Advertisement

loading
Need help?

Need help?

Do you have a question about the Mouvex AF TM H Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PSG Dover Mouvex AF TM H Series

  • Page 1 INSTRUCTIONS 1005-C00 e Section 1005 Effective September 2018 Replaces December 2012 Translation of the original instructions Pump AF TM H INSTALLATION OPERATION MAINTENANCE WARRANTY : TM Series pumps are covered 24 months by warranty within the limits mentioned in our General Sales Conditions. In case of a use other than that mentioned in the Instructions manual, and without preliminary agreement of MOUVEX, warranty will be canceled.
  • Page 2: Installation

    INSTALLATION D : Bypass E : Bypass cap F : Fixing stud and nut G : Bearing nipple Rotation Motor protection MOUVEX pump is reversible. Suction and discharge ends As the bypass protects the pump only, electric motors should are bound to rotation as indicated on plate fixed to pump. be equipped with their own protection device.
  • Page 3 UTILISATION Temperature of pumped product Delivery adjustement AF TM H pumps are suitable for pumping domestic fuel and When the pump does not deliver the proper flow rate, the heavy fuel heated up to 0° C and 180° C with the following trouble may come from bypass spring not being adjusted at recommandations : the correct pressure setting.
  • Page 4 DISASSEMBLY / REASSEMBLY Serial Nbr Bypass fastening Disassembly Reassembly Opening the pump : Reassembly is undertaken in the reverse order of dismant- ling. Before assembling, check that spring 504 of piston bea- • Remove end-plate bolts 409. ring 503 and piston backsprings 310 has not weakened. •...
  • Page 5: Shaft Seal

    SHAFT SEAL Operation Reassembly MONOSIR block 601 is held in shaft by its rubber face. • Check rings 707, 605 and rubber faces of block 601. Stationary seal 604 is held in pump body by ring 605. Tight • Check that sealing faces of 604 and block 601 are flat and sealing depends on : mirror smooth.
  • Page 6 STORAGE Restarting If necessary, refer to § DISASSEMBLY / REASSEMBLY for pump disassembly. Follow the standard start-up procedure for the pump/ motor-driven pump, as well as the instructions below. Short duration (≤ 1 month) Turn the pump by hand to make sure the parts move freely.
  • Page 7: Certificate Of Conformity

    CERTIFICATE OF CONFORMITY NT 1005-C00 09 18 Pump AF TM H e...