2. Assembly and installation

2.1 Preparatory work

Figure 1 – Housing top view and position of the wire/cable inlets (i) – (viii)
First remove the keyboard (6). To do this, loosen the 4 screws (8), lift the keyboard (6) carefully and separate the connector
(7) between keyboard (6) and the circuit board located in the interior of the housing.
If you want to operate a headset or use the relay onboard output contact or operate the phone with an external DC power
supply, replace the dummy plugs of the cable/wire inlets (iii), (iv) and/or (v) with suitable wire/cable inlets.

2.2 Wall mounting

Figure 2 – Wall mounting
Attach the phone cradle (1) with 4 screws (2) to the wall in such a way that the higher part of the phone cradle (1) points
downward. In the process, place the washers Ø 18 mm that have been provided under the screw heads.
Hang up the phone in the top locking hooks (A) of the phone cradle (1) and swivel the phone downward until the bottom
locking hooks (B) of the phone cradle (1) audibly engage.
Screw in the two pre-installed safety screws (3) in the terminal compartment (see figure 1) as far as they will go to ensure
that an IP65 degree of protection is achieved.
8
USER MANUAL FERNTEL IP4 / IP160 March 2022 www.eaton.com