BUSCH SAMOS SI 0045 E 1 Instruction Manual

BUSCH SAMOS SI 0045 E 1 Instruction Manual

Side channel blowers

Advertisement

Instruction Manual
2 en 27.10.2021 Original instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAMOS SI 0045 E 1 and is the answer not in the manual?

Questions and answers

Summary of Contents for BUSCH SAMOS SI 0045 E 1

  • Page 1 Instruction Manual 2 en 27.10.2021 Original instructions...
  • Page 2: Table Of Contents

    Preface ....... 2 Congratulations on your purchase of the Busch side channel blower.
  • Page 3: Product Description

    Conveying media with a lower or higher density than air leads to an in- The side channel blower is cooled by creased thermal and/or mechanical load on the side channel blower and is permissible only after prior consultation with Busch. – radiation of heat from the surface of the side channel blower The gas shall be free from vapours that would condensate under the –...
  • Page 4: Safety Notes

    VCI-products may attack the surfaces of plastics and elastomers. Seek flated cushions: advice from your local packaging dealer! Busch uses CORTEC ◆ Remove the inflated cushions from the box VCI 126 R film for the overseas packaging of large equipment.
  • Page 5: Installation And Commissioning

    Seek advice from your Busch representative! In case the vacuum shall be maintained after shutdown of the side channel blower: ◆...
  • Page 6: Pressure Connection

    Seek advice from your Busch representative! ● Fasten the side channel blower at its location ● Make sure that the discharge line either slopes away from the side...
  • Page 7: Connecting Lines/Pipes

    Conveying media with a lower or higher density than air leads to an in- creased thermal and/or mechanical load on the side channel blower DANGER and is permissible only after prior consultation with Busch. _age32 The gas shall be free from vapours that would condensate under the In case the side channel blower conveyed gas that was contami- temperature and pressure conditions inside the side channel blower.
  • Page 8: Maintenance Schedule

    Particularly heavy duty operation, such like high dust loads in the envi- ronment or in the process gas, other contaminations or ingress of pro- Busch service will only accept side channel blowers that come with a cess material, can make it necessary to shorten the maintenance completely filled in and legally binding signed “Declaration of...
  • Page 9: Spare Parts

    If an overhaul re- Pressure relief valve, pressure side 0917 149 553 quires parts other than bearings or standard parts your Busch SI 0500-1150 E1/E2 representative will clarify whether an overhaul is economic or a re- Auxiliary silencer, connection thread G1¼,...
  • Page 10: Troubleshooting

    Long suction, discharge or pressure line with Use larger diameter too small diameter Internal parts are worn or damaged Repair the side channel blower (Busch service) The gas conveyed by the side channel blower Process components evaporating under vac- Check the process, if applicable...
  • Page 11 Try to turn the drive motor with the side channel blower by hand If the side channel blower is blocked: Repair the side channel blower (Busch service) The drive motor is defective Replace the drive motor (Busch service) The side channel blower is blocked...
  • Page 12 Insufficient gas transfer Vacuum operation: Provide a vacuum relief valve Pressure operation: Provide a pressure relief valve Mains frequency or voltage outside tolerance Provide a more stable power supply range Adjust, repair or replace, respectively In case a vacuum relief valve/regulating system is installed: The vacuum relief valve/regulating system is misadjusted or defective...
  • Page 13: Eu-Declaration Of Conformity

    This Declaration of Conformity and the CE-mark affixed to the nameplate are valid for the machine within the Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer. When this machine is integrated into a superordinate machinery the manufacturer of the superordinate machinery (this can be the operating company, too) must conduct the conformity assessment process for the superordinate machine or plant, issue the Declaration of Conformity for it and affix the CE-mark.
  • Page 14: Uk Declaration Of Conformity

    This Declaration of Conformity and the UKCA-mark affixed to the nameplate are valid for the machine within the Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer. When this machine is integrated into a superordinate machinery the manufacturer of the superordinate machinery (this can be the operating company, too) must conduct the conformity assessment process for the superordinate machine or plant, issue the Declaration of Conformity for it and affix the UKCA-mark.
  • Page 15 blank page page 15...
  • Page 16 Busch Vacuum Solutions We shape vacuum for you. Argentina Denmark Malaysia South Africa info@busch.com.ar info@busch.dk busch@busch.com.my info@busch.co.za Australia Finland Mexico Spain sales@busch.com.au info@busch.fi info@busch.com.mx contacto@buschiberica.es Austria France Netherlands Sweden busch@busch.at busch@busch.fr info@busch.nl info@busch.se Bangladesh Germany New Zealand Switzerland sales@busch.com.bd info@busch.de sales@busch.co.nz...

This manual is also suitable for:

Samos si 0090 e 1Samos si 0090 e 2Samos si 0150 e 1Samos si 0150 e 2Samos si 0210 e 1h0 urSamos si 0210 e 1h0 ue ... Show all

Table of Contents