Group II, for non-mining applications, and is permissible only after prior consultation with Busch. in the process gas and in the environment explosive atmosphere in the form of a cloud of combustible dust in air not likely to occur in normal According to the directive /E (“ATEX...
Prior to handling the side channel blower these installation and oper- tightening straps: ating instructions shall be read and understood. If anything remains to be clarified please contact your Busch representative! ◆ Remove the tightening straps Safety Notes In case the side channel blower weighs less than 20 kg and comes...
However, VCI-products may attack the surfaces of plastics and elastomers. Seek advice from your local packaging dealer! Busch uses CORTEC VCI 126 R film for the overseas packaging of large equipment. ● Wrap the side channel blower in VCI film ●...
Seek advice from your Busch representative! Electrical circuits in zone 1 (outside) shall be executed intrinsically safe In case the vacuum shall be maintained after shutdown of the side in protection class ib acc.
Conveying media with a lower or higher density than air leads to an in- creased thermal and/or mechanical load on the side channel blower and is permissible only after prior consultation with Busch. According to the directive /E (“ATEX ”) the side...
10 percent at 40 °C. In case of blower by Busch. placement in altitudes beyond 1000 m above sea level the allowed dif- ferential pressure shall be agreed upon with Busch. The side channel blower is intended for continuous operation. Frequent DANGER _age32 switching on and off increase the coil temperature.
In case of operation in a dusty environment: Busch service will only accept side channel blowers that come with a ◆ Clean as described under Ú page 8: Every 6 Months: completely filled in and legally binding signed “Declaration of Contam- ination”...
Risk of explosion in case of operation of faulty equipment! A faulty side channel blower must immediately be removed from service. In case of faults the cause of which cannot be determined the Busch service must be contacted. WARNING Risk of electrical shock, risk of damage to equipment.
Page 11
Try to turn the drive motor with the side channel blower by hand If the side channel blower is blocked: Repair the side channel blower (Busch service) The drive motor is defective Replace the drive motor (Busch service) The side channel blower is blocked...
Busch – All over the World in Industry www.buschvacuum.com Australia New Zealand Dr.-Ing. K. Busch GmbH Außenstelle Neuenrade Busch Australia Pty. Ltd. Busch New Zealand Ltd. Breslauer Str. 36 30 Lakeside Drive Unit D, 41 Arrenway Drive 58809 Neuenrade Broadmeadows, Vic. 3047...