GEMO
Attention, Risk of,
Danger, Warning
•
Dimensions
•
Panel Cut-out
•
Display
•
Sensor Type
•
Measuring Scale
•
Resolution
•
Accuracy
•
Control Form
•
Out Output
•
Alarm Output
•
Heat SET
•
Alarm SET
•
Heat Hysteresis
•
Alarm Hysteresis
•
Proportional Band
•
Integral Time
•
Derivative Time
•
Control Period
•
Offset
•
Heating/Cooling
•
Cold. Junc. Comp.
•
Line Comp.
•
Sensor Failure
•
Supply Voltage
•
Power Consumption : < 8VA
•
Humidity
•
Altitude
•
EMC
•
Safety
•
Protection Class
•
Temperature Spec.
•
Weight
•
Torque for screwing : Max. 0.5 N.m
WARNING :
if 2 wire Pt100 is used, connect compensation lead
to measuring lead: (DT109 / DT105 / DT106:17-18,
DT107: 13-14, DT104: 10-11)
no: normally open
nc: normally closed
DT109AX / DT107AX / DT106AX / DT105AX / DT104AX
AUTO-TUNE PID TEMPERATURE CONTROLLER
High Voltage,
Risk of Electric Shock
TECHNICAL SPECIFICATION
: DT109:96x96, DT107:72x72, DT105/DT106:48x96, DT104:48x48mm
: DT109:91x91, DT107:68x68, DT105/DT106:93,5x45,5, DT104:45,5x45,5mm
: 4 Digits 7 Segment (PV), 4 digits 7 Segment (SV)
: J,K,T,S,R type T/C, Pt100 selectable
o
: -100..600
C, J type T/C (Inpt=J),
o
-100..1300
C, K type T/C (Inpt=k), -100.0..999.9
o
-100..400
C, T type T/C (Inpt=t),
o
0..1750
C, S type T/C (Inpt=S)
o
-100..600
C, Pt100, (Inpt=Pt)
o
o
: ± 1
C or ± 0.1
: ± 1 % (Over full scale)
: ON-OFF or P, PI, PD, PID - selectable
: Relay (NO + NC), 250VAC, 2A, Resistive load, (optional SSR)
: Relay (NO + NC), 250VAC, 2A, Resistive load, (only NO for DT104)
: Lower Limit .. Upper Limit
: AL.tY = Abs,-Abs; Lo.L .. UP.L
AL.tY = rel, -rel, bnd, -bnd, bn.i, -bn.i; -100 .. +100 / -100.0 .. +100.0
: 0 .. 50 / 0.0 .. 50.0
: 1 .. 50 / 0.1 .. 50.0
o
: 5 .. 150
C (Pb.C)
: 0:00 .. 30:00 min:sec. (OFF if set to 0:00)
: 0:00 .. 10:00 min:sec. (OFF if set to 0:00)
: 1 .. 200 sec. (Ct)
o
: -100..+100
C / -100.0 .. +100.0
: Selectable (only ON-OFF control form is active for cooling)
o
: 0 .. 50
C (T/C)
: 10 Ohm max. (3 wire Pt100)
: OUT output is active according to P.Err and Ct parameters in case of
sensor failure, measurement out of range or hardware fails to measure
input signal (OUT output is OFF if Perr is 0). For Alarm look "Alarm Output".
: 100..240VAC, 50-60Hz or (24VDC/AC; isolation voltage: 40VAC max.)
: < 70% (non-condensing)
: < 2000 m
: EN 61000-6-1, EN 61000-6-3 (Only light industrial environment)
: EN 61010-1; Pollution degree 1, measurement category I, (Only light industrial
environment, double/reinforced isolated, non-conductive pollution environment)
: IP20; according to EN 60529
: Operating: 0 .. 50
: < 0.5 kg
Double / Reinforced
Insulation
-100.0 .. 600.0
-100.0 .. 400.0
0 .. 1750
-100.0 .. 600.0
C
o
C (H.Set)
o
C (A.Set)
o
C (H.Hys); PID is active if set to 0
o
C (A.Hys)
o
C (oFFS)
o
o
C, Storage -10
C .. 60
NOT
CE Mark
Litter
o
C, J type T/C (Inpt=J.0)
o
C, K type T/C, (Inpt=k.0)
o
C, T type T/C (Inpt=t.0)
o
C, R type T/C (Inpt=r)
o
C, Pt100, (Inpt=Pt.0)
o
C (no icing)
o
C