GEMO
Attention, Risk of,
Danger, Warning
•
Dimensions
•
Panel Cut-out
•
Display
•
Sensor Type
•
Measuring Scale
•
Resolution
•
Accuracy
•
Control Form
•
Out Output
•
Alarm Output
•
Time SET
•
Timer Resolution
•
ALARM ON SET
•
ALARM ON SET resol.: 1 second
•
Timer Accuracy
•
Timer Threshold
•
Heat SET
•
Heat Hysteresis
•
Proportional Band
•
Integral Time
•
Derivative Time
•
Control Period
•
Offset
•
Cold. Junc. Comp.
•
Line Comp.
•
Sensor Failure
•
Supply Voltage
•
Power Consumption : < 8VA
•
Humidity
•
Altitude
•
EMC
•
Safety
•
Protection Class
•
Operation Temp.
•
Storage Temperature : -10
•
Weight
•
Torque for screwing : Max. 0.5 N.m
WARNING:
if 2 wire Pt100 is used, connect compensation
lead to measuring lead: (TTX109:17-18, TT107X: 13-14,
TT104X: 10-11)
no: normally open
nc: normally closed
AUTO-TUNE PID TEMPERATURE CONTROLLER & TIMER
High Voltage,
Risk of Electric Shock
TECHNICAL SPECIFICATION
: TT109X:96x96, TT107X:72x72, TT104X:48x48mm
: TT109X:91x91, TT107X:68x68, TT104X:45,5x45,5mm
: 4 Digits 7 Segment (PV), 4 digits 7 Segment (SV)
: J,K,T,S,R type T/C, Pt100 selectable
o
: -100 .. 600
C, J type T/C, (Inpt=J), -100 .. 1300
o
-100 .. 400
C, T type T/C, (Inpt=t),
o
0 .. 1750
C, R type T/C, (Inpt=r),
-99.9 .. 600.0
o
: ± 1
C or ± 0.1
: ± 1 % (Over full scale)
: ON-OFF or P, PI, PD, PID - selectable
: Relay (NO + NC), 250VAC, 2A, Resistive load, (optional SSR)
: Relay (NO + NC), 250VAC, 2A, Resistive load, (only NO for TTX104)
: 00:00 .. 99:59 hours (t.SET)
: 1 minute
: 00:00 .. 99:59 minutes (A.Off). Set to 00:00 for latch ALARM output
: ± % 1.5 (of SET or A.Off values)
o
: 0 .. UP.L
C (t.Hys)
: Lower Limit .. Upper Limit
o
: 0 .. 100
C (H.Hys); PID is active if set to 0
o
: 1 .. 130
C (Pb.C)
: 0 .. 30,0 min. (OFF if set to 0)
: 0.. 10,0 min. (OFF if set to 0)
: 1 .. 200 sec. (Ct)
o
: -100..+100
C (oFFS)
o
: 0 .. 50
C (T/C)
: 10 Ohm max. (3 wire Pt100)
: OUT is active according to P.Err and Ct parameters in case of sensor
failure, measurement out of range or hardware fails to measure input signal
(OUT is OFF if Perr is 0). Alarm output depends on parameter selection.
: 100..240VAC, 50-60Hz or 24VDC/AC (isolation voltage: 40VAC max.)
: < 70% (non-condensing)
: < 2000 m
: EN 61000-6-1, EN 61000-6-3 (Only light industrial environment)
: EN 61010-1; Pollution degree 1, measurement category I, (Only light industrial
environment, double/reinforced isolated, non-conductive pollution environment)
: IP20; according to EN 60529
o
: 0 .. 50
C
o
o
C .. 60
C (no icing)
: < 0.5 kg
TT109X / TT107X / TT104X
Double / Reinforced
Insulation
0 .. 1750
-100 .. 600
o
C, Pt100, (Inpt=Pt.0)
o
C
o
C (H.Set)
NOT
CE Mark
Litter
o
C, K type T/C, (Inpt=k)
o
C, S type T/C, (Inpt=S)
o
C, Pt100, (Inpt=Pt)
Need help?
Do you have a question about the TT109X and is the answer not in the manual?
Questions and answers