Toshiba V Series User Manual page 97

Integrated controller
Hide thumbs Also See for V Series:
Table of Contents

Advertisement

6F8C0945
Error: 8198
Shutdown routine notification error
Message
Can't notify shutdown routine. (%1) %n
---
%1: Device name
Data
None
Description
Shutdown routine notification error has occurred.
Error: 8199
Memory parity error detected
Message
Parity error. Memory cleared. (%1) %n
---
%1: Device name
Data
0: Error address1: Error data (high end doubleword)
2: Error data (low end doubleword)
3: parity register
Description
Memory parity error has been detected during driver initiation
and memory has been cleared.
Error: 8200
Station address setting abnormal
Message
Station address set error. %n
Data
0: Station address
Description
Station address is set to 0x00 or 0xFF.
Error: 8201
Station address overlapped
Message
Station address overlapped. %n
Data
0: Station address
Description
Station address of multiple PCI bus cards are overlapping.
Error: 8448
Non supported interrupt occurred
Message
Non support interrupt occurred. (%1) %n
---
%1: Device name
Data
None
Description
Non-supported interrupt has occurred.
9
85

Advertisement

Table of Contents