Unscrew the 3 screws and remove the analysis block.

11.12. Removal of Synthesis Mirror

(1)
Remove the upper case according to the section 11.2. "Removal
of Upper Case".
(2)
Unscrew the 2 screws and remove the CW fan fixing metal with
fan and the cooling plate.
(3)
Unscrew the 1 screw and remove the grounding terminal.
(4)
Unhook the 4 hooks and remove the analysis case cover.
Notes:
· Work carefully not to deform the hooks of the analysis
case cover.
· When the analysis case cover is removed, be careful
not to touch the rod.