Install A Solar Sensor (If Applicable); Install Additional Low Voltage Equipment (I.e., Heater Connection); Install Iaqualink (If Applicable); Mount The Iaqualink Device - Polaris PAC PAGAUT Owner's Manual

Above-ground pool automation control
Table of Contents

Advertisement

Available languages

Available languages

Pool Automation Control | Owner's Manual
Polaris
®
PAC
5.3

Install a Solar Sensor (if applicable)

If there is a solar panel in the equipment configuration,
wire the solar panel temperature sensor to the 10-pin
green connector. The solar sensor should be installed
adjacent to the solar panel so it will sense the same
temperature as the solar panels. Do not install in the
pipe.
1. Feed the sensor wire through the black low
voltage wiring knockout.
2. Strip 1/4" of insulation and separate the wires.
3. Connect sensor wires to pins 3 and 4.
5.4
Install Additional Low Voltage
Equipment (i.e., Heater Connection)
If there is additional low voltage equipment installed,
such as low voltage heating, wire to pins 1 and 2 on the
10-pin green connector.
5.5
Install iAquaLink
NOTE: For complete intructions and safety information,
refer to the iAquaLink Quick Start Guide
(included in the iAquaLink packaging), or the
full iAquaLink manual (found online at
www.PolarisPool.com).
5.6

Mount the iAquaLink Device

Mount the iAquaLink at least 6 feet off the ground and at
least 8 feet from motors, such as a blower.
5.7

Wire the iAquaLink Device

Wire the iAquaLink device on the red RS-485 connector.
1. Feed wire through the black low voltage wiring
knockout.
2. Connect four (4) separate wires to each terminal.
Red 4-Pin Terminal Bar
NOTE: Wire only two (2) devices (e.g, the iAquaLink
and one additional device) to the RS-485
connector. If you have more than one additional
device in your equipment configuration, use a
multiplex board.
5.8
Install Jandy Valve
(if applicable)
You may wire up to a JVA on the PAC to control a water
feature or solar panel, for example.
(if applicable)
4 Green
3 Yellow
2 Black
1 Red
®
Actuators (JVAs)
You may wire up to a JVA on the PAC to control a water
feature or solar panel, for example.
NOTE: Read and follow complete installation
instructions and safety information in the Jandy
Valve Actuator owner's manual (included in the
JVA packaging).
1. Install JVA on equipment lines according to
installation instructions in the owner's manual.
2. Feed intake JVA wire through the black low
voltage wiring knockout.
3. Plug JVAs to Solar socket.
4. If the solar sensor is installed the solar JVA will
automatically assign to Solar Heat. If solar sensor
is not installed the solar JVA may be assigned to
one of the three (3) assemblies.
Section 6. User Interface
All system programming and installation setup is
performed through the automation system user interface
UI.
Menu Screen
Back Button
Power Button
6.1

Navigation Buttons

Use the following buttons on the user interface to
access and select all menus and commands:
On/Off
Turn user interface power on/off.
Up/Down
Scroll up/down within current menu to
highlight a specific menu command.
Back
Go back to previous menu. To return to Main
menu, press Back button repeatedly.
Select
Select current highlighted menu command.
Display the next menu or activate the
selected function.
ENGLISH
Up/Down (Scroll)
Arrows
Select Button
Page 7

Advertisement

Table of Contents
loading

Table of Contents