Industrial Router Pro Series UR32 Quick Start Guide...
Page 2
Safety Precautions Milesight will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide. The device must not be modified in any way. Do not place the device close to objects with naked flames.
Page 3
Revision History Date Doc Version Description Apr. 26, 2019 V 1.0 Initial version May 11, 2020 V 1.1 Web interfaces upgrade Nov. 25, 2020 V 2.0 Layout Replace 1. DI matches to GND Dec. 1, 2021 V 2.1 2. Update cellular pictures...
1. Packing List Before you begin to install the UR32 router, please check the package contents to verify that you have received the items below. 2 × Magnetic Cellular 1 × UR32 1 × Ethernet Cable 1 × Power Adapter Antennas 1 ×...
2. Hardware Introduction 2.1 Overview Main Cellular Antenna Connector GPS/WIFI Antenna Connector AUX Cellular Antenna LED Indicator Area POWER: Power Indicator SYSTEM: Status Indicator SIM : Status Indicator : Signal Strength Indicator Serial Port & I/O Ethernet LAN1/WAN Port Ethernet LAN2 Port Power Connector SIM and Reset Button Holder 2.2 Dimensions (mm)
2.3 Serial & IO & Power Pinouts RS232 Description /RS485* Digital Output Digital Input Ground Common Ground RXD/B Receive Data TXD/A Transmit Data Description Wire Color Positive Negative Black *: Only for -485 model. 2.4 LED Indicators Indication Status Description The power is switched off POWER Power Status...
antenna to a suitable location to get better signal) Static/Static/Off: normal signals with 11-20 ASU (average signal strength) Static/Static/Static: strong signals with 21-31 ASU (signal is good) 2.5 Reset Button Reset button is under the SIM slots. Description Function SYSTEM LED Action Blinking Press and hold the reset button for more than 5 seconds.
3.3.2 DIN Rail Mounting (Measured in mm) Use 2 pcs of M3 × 6 flat head Phillips screws to fix the mount clip to the router, and then hang the device to the DIN rail. The width of DIN rail is 3.5cm. Recommended torque for mounting is 1.0 N·m, and the maximum allowed is 1.2 N·m.
4. Log in the Web GUI of Router Please connect PC to LAN port of UR32 router. PC can obtain an IP address, or you can configure a static IP address manually. The following steps are based on Windows 10 operating system for your reference.
Page 12
D. Enter the username, password, and click "Login". If you enter the username or password incorrectly more than 5 times, the login page will be locked for 10 minutes. E. When you login with the default username and password, you will be asked to modify the password. It’s suggested that you change the password for the sake of security.
5. Network Configuration This chapter explains how to connect UR32 to network via WAN connection or cellular. 5.1 Ethernet WAN Configuration A. Go to “Network > Interface > Port” to change LAN1 to WAN port. B. Go to “Network > Interface > WAN” to select connection type and configure WAN parameters, click “Save &...
5.2 Cellular Connection Configuration Take inserting SIM card into SIM1 slot as an example; please refer to the following detailed operations. A. Go to “Network > Interface > Cellular > Cellular Setting” to configure APN, PIN code or other cellular info, click “Save”...
Page 15
D. Click “Status > Cellular” to view the status of the cellular connection. If it shows “Connected”, it means SIM1 has dialed up successfully. On the other hand, you can check the status of SIM indicator. If it keeps on green light statically, it means SIM1 has dialed up successfully. E.