Si001272EC

2. Electrical Box

Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
1
Remove the screw on
the partition plate (1).
2
Remove the screw on
the stop valve mounting
plate.
3
Remove the 2 screws
to detach the earth/
ground wires.
4
Disconnect the
connector [S70].
5
Release the 4 clamps
attached to the
electrical box.
Removal Procedure
All manuals and user guides at all-guides.com
Procedure
Partition plate (1)
Stop valve
mounting plate
[S70]
Points
(R16917)
Earth/ground
wire
(R18969)
[S70]: fan motor
When reassembling, insert
each clamp into the hole.
For the fan
motor harness
For the thermistor
ASSY harnesses
Some models do not have a
(R23989)
harness for four way valve
coil.
Electrical Box
For the electronic
expansion valve coil
harness
For the four way
valve coil
harness
(R23990)