Components
Triple surface unit:
Right Front(RF) Element
Copyright ©
LG Electronics Inc. All rights reserved.
Only training and service purposes
Test procedures
1. Refer to page 3-8 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the (E1 & 1A)
and (E2 & 1A) and (E3 & 1A)
The meter should indicate.
- (E3 & 1A) → 52 Ω ± 10%
- (E2 & 1A) → 52 Ω ± 10%
- (E1 & 1A) → 64 Ω ± 10%
5. Touch the ohmmeter test leads to limiter terminals
1A and 2A.
The meter should indicate continuity(0Ω)
6. Touch the ohmmeter test leads to limiter terminals
1B and 2B. With the temperature below 150 ˚F, the
meter should indicate an open circuit(infinite).
With the temperature above 150 ˚F, the meter
should indicate continuity (0Ω).
4-12
Results
Normal: Approximately 52 Ω
Normal: Approximately 52 Ω
Normal: Approximately 64 Ω
Normal: Continuity
(below 0.5 Ω)
If not replace
Below 150˚F
→ open circuit(infinite).
Above 150˚F
→ continuity (0 Ω)