Disassembly Procedure
1. Removal of Mounting Unit
1. Unscrew 2 screws (A) so that the mounting unit can
be removed.
SCREWS (A)
2. Removal of Microphone Holder
1. Loosen screw (B) and then open the Microphone
holder.
2. Unscrew 2 screws (C) so that the Microphone
holder can be removed.
3. Removal of Eyepiece Rubber
4. Removal of Eyepiece Unit
SCREW (B)
SCREWS
(C)
NOTE: For assembling the Eyepiece Unit, make
DIS-1
1. Tear off the points of Eyepiece rubber (A) as
shown below.
(A)
1. Turn the Lock ring counterclockwise.
2. Pull out the Eyepiece Unit.
Guideline
sure each Guideline.
(A)
LOCK RING