MODEL
TYPE
RATINGS 2
Input BTUH 3
Capacity BTUH (ICS) 3
Temp. rise (Min.-Max.) °F.
AFUE (Upflow / Horizontal)
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
COMBUSTION FAN - Type
Drive - No. Speeds
Motor HP - RPM
Volts / Ph / Hz
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT PIPE DIAMETER —
Min (In.) 56
HEAT EXCHANGER
Type - Fired
- Unfired
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICE
Type
BURNERS — Type
Number
POWER CONN. — V / Ph / Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection
(Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs.)
Notes
1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3.
2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
5 Refer to the Vent Length Table in the Installer's Guide or the Allowable Vent Length label located on the furnace.
6 All *UH1 and *DH1 furnace models have a vent outlet diameter that equals 2".
2

PRODUCT SPECIFICATIONS

*UH1C080A9601C
Upflow / Horizontal
80,000
76,000
30 - 60
95 / 94.2
DIRECT
11 x 10
1
4
See Fan Performance Table
See Fan Performance Table
3/4
1100
115/1/60
Centrifugal
Direct - 1
1/20 - 3450
115/1/60
0.71
No
High Velocity
1 - 20x25 - 1in.
3 Round
Aluminized Steel - Type I
20
4 — 45
4 — 56
Redundant - Single Stage
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
4
115/1/60
13.5
20
1/2
H x W x D
41-3/4 x 23 x 30-1/2
171 / 160
*UH1C100A9481C
Upflow / Horizontal
97,000
92,150
35 - 65
95 / 94.2
DIRECT
10 x 10
1
4
See Fan Performance Table
1/2
1075
115/1/60
Centrifugal
Direct - 1
1/20 - 3450
115/1/60
0.71
No
High Velocity
1 - 20x25 - 1in.
3 Round
Aluminized Steel - Type I
Aluminized Steel - Type I
20
5 — 45
5 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
5
115/1/60
12.5
20
1/2
H x W x D
41-3/4 x 23 x 30-1/2
41-3/4 x 26-1/2 x 30-1/2
171 / 160
1
*UH1D100A9601C
*UH1D120A9601C
Upflow / Horizontal
Upflow / Horizontal
97,000
92,150
35 - 65
95 / 94.2
DIRECT
11 x 10
1
4
See Fan Performance Table
3/4
1100
115/1/60
Centrifugal
Direct - 1
1/20 - 3450
115/1/60
0.71
No
High Velocity
1 - 24x25 - 1in.
3 Round
Aluminized Steel - Type I
20
5 — 45
5 — 56
Redundant - Single Stage
Hot Surface Ignition
Hot Surface Ignition
Multiport Inshot
5
115/1/60
12.9
20
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
197 / 185
110,000
104,500
40 - 70
95 / 94.2
DIRECT
11 x 10
1
4
3/4
1100
115/1/60
Centrifugal
Direct - 1
1/20 - 3450
115/1/60
0.71
No
High Velocity
1 - 24x25 - 1in.
3 Round
20
6 — 45
6 — 56
Multiport Inshot
6
115/1/60
12.9
20
1/2
H x W x D
205 / 193
UH1-DH1-SF-1L

Hide quick links: