Parameter overview with brief description
Parameter
Volume flow unit
Select the unit for the volume flow.
Volume unit
Select the unit for the volume.
Temperature unit
Select the unit for the temperature.
Totalizer unit
Select the unit for the totalizer.
Conductivity unit
Select the unit for conductivity.
Parameter overview with brief description
Parameter
Description
Installation
Select the installation
direction
direction.
On value
Enter the on value for
low flow cut off.
Damping
Enter the time constant
for damping the flow
measured value.
Endress+Hauser
Menu: "Guidance" → System units
Description
9.3.3

Setting the installation direction and measurement

The Sensor submenu contains parameters for specific settings of the measuring device.
Navigation
Menu: "Guidance" → Sensor
• Flow in arrow direction (forwards)
Positive flow measurement in the direction of the arrow.
• Flow against arrow direction (backwards)
Positive flow measurement in the opposite direction of the arrow.
Positive floating point number
A flow measured value that is less than the value of the on value
forces the display to zero. In the event of plant downtime, this
prevents the totalizer from continuing to totalize even though
there is no flow.
The measured value flashes on the display when low flow cut off is
active.
Low flow cut off is deactivated again as soon as the flow measured
value exceeds 1.5 times the on value.
0 to 10 s
Selection
• l/s, m³/h, l/min, l/h
• gal/min (us), fl. oz/min
• ml, l, m³
• fl. oz (us), gal (us)
• °C
• °F
• ml, l, m³
• kl, Ml
• fl. oz (us), gal (us)
• kgal (us)
• µS/cm
• S/m
• mS/cm
Selection/input
Commissioning
Factory setting
l/min
ml
°C
µS/cm
Factory setting
Flow in arrow direction
(forwards)
Depends on the nominal
diameter:
DN 15 (½"):
0.05 l/min (0.013 gal/min)
DN 20 (¾"):
0.1 l/min (0.026 gal/min)
DN 25 (1"):
0.2 l/min (0.052 gal/min)
DN 50 (2"):
1.5 l/min (0.4 gal/min)
0 s
23