3

SPECIFICATIONS

3-1. SPECIFICATIONS
Service Ref.
Power source
Cooling capacity
(Nominal)
Power input
Current input
Heating capacity
(Nominal)
Power input
Current input
External finish
External dimension H × W × D
Net weight
Grille
External finish (Panel)
Dimension
H × W × D
Net weight
Heat exchanger
FAN
Type × Quantity
External static press. in. WG
Motor type
Motor output
Driving mechanism
Airflow rate
(Low-Mid2-Mid1-
High)
Sound pressure level
(Low-Mid2-Mid1-High)
(measure in anechoic room)
Insulation material
Air filter
Protection device
Refrigerant control device
Connectable outdoor unit
Diameter of refrigerant
Liquid
pipe (O.D.)
Gas
Field drain pipe size
Standard attachment
Document, accessory
Optional parts
Air outlet shutter plate
High efficiency filter element
Multi-function casement
Remarks
Installation
*1
Nominal cooling conditions
Indoor: 80°F D.B./67°F W.B
[26.7°C D.B./19.4°C W.B ]
Outdoor: 95°F D.B.
[35°C D.B.]
Pipe length: 25 ft [7.6m]
Level difference: 0 ft [0 m]
Note: Specifications are subject to change without notice.
OCH746A
PLFY-EP06NEMU-ER1.T PLFY-EP08NEMU-ER1.T PLFY-EP12NEMU-ER1.T PLFY-EP15NEMU-ER1.T
*1
Btu/h
6,000
1.8
*1
kW
kW
0.02
A
0.19
*2
Btu/h
6,700
2.0
kW
*2
kW
A
0.14
in
mm
lbs [kg]
in
mm
lbs [kg]
Pa
in. WG
Pa
kW
cfm
300-424-459-494
m³/min
8.5-12.0-13.0-14.0
142-200-217-233
L/s
dB <A>
19-23-25-27 (208-230 V)
in [mm]
in [mm]
in [mm]
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items
shall be referred to the Installation Manual.
*2
Nominal heating conditions
70°F D.B.
[21.1°C D.B.]
47°F D.B./43°F W.B
[8.3°C D.B./6.1°C W.B]
25 ft [7.6m]
0 ft [0 m]
1-Phase 208–230 V, 60 Hz
8,000
2.4
9,000
2.7
0.02
Galvanized steel sheet
10-3/16 × 33-1/16 × 33-1/16
258 × 840 × 840
46 [21]
PLP-41EAEU: Munsell 1.0Y 9.2/0.2
1-9/16 × 37-13/32 × 37-13/32
40 × 950 × 950
11 [5]
Cross fin
Turbo fan × 1
0.000 (208 V)
0
0.000 (230 V)
0
DC motor
0.050
Direct drive
494-530-565-600
14.0-15.0-16.0-17.0
233-250-267-283
27-29-30-31 (208–230 V)
PS
PP honeycomb (long life filter, anti-bacterial type)
Fuse
LEV
R410, CITY MULTI
1/4 [6.35] Flare
1/2 [12.7] Flare
O.D 1-1/4 [32]
Installation Manual, Instruction Book
PAC-SJ37SP-E
PAC-SH59KF-E
PAC-SJ41TM-E
12
12,000
15,000
3.5
4.4
0.03
0.31
13,500
17,000
4.0
5.0
0.26
530-547-565-600
15.0-15.5-16.0-17.0
250-258-267-283
28-29-30-31 (208–230 V)
Unit converter
kcal/h = kW × 860
Btu/h = kW × 3,412
3
cfm = m
/min x 35.31
lb = kg/0.4536
Above specification data is
subject to rounding
variation.