1. For inlet pressure in excess of 1000 psig / 69.0 bar, refer to the maximum body and disk pressure ratings in the Specifications section.
2. For pressure settings under 10 psig / 0.69 bar, inlet pressure should be limited to approximately 100 psig / 6.9 bar so the setpoint adjustment can be obtained.
3. Only available with 9/16 in. / 14.3 mm orifice. If a smaller orifice is installed the unit will not achieve published capacities.
MAXIMUM PRESSURE DESCRIPTION
Maximum pressure to spring and diaphragm casings
to prevent leak to atmosphere other than relief action
(internal parts damage may occur)
Maximum pressure to spring and diaphragm casings to
prevent burst of casings duringabnormal operation (leak to
atmosphere and internal parts damage may occur)
Maximum diaphragm casing overpressure (above setpoint) to
prevent damage to internal parts
1. If the spring case is pressurized, a metal adjusting screw cap is required. Contact your local Sales Office for details.
4
ADJUSTING SCREW
DIAPHRAGM
PUSHER POST
LEVER
Figure 2. Type 627BM Operational Schematic
Table 1. Maximum Inlet Pressures and Outlet Pressure Ranges
SPRING
PART
NUMBER
bar
0.34 to 1.4
10B3076X012
1.0 to 2.8
10B3077X012
2.4 to 5.5
10B3078X012
4.8 to 10.3
10B3079X012
9.7 to 17.2
10B3078X012
16.5 to 34.5
10B3079X012
Table 2. Maximum Spring and Diaphragm Casing Pressure