8-3. RS-232 Output Format

Baud Rate : 2400, 4800, 9600
Data Bit
: 8
Parity
: N ( None )
Stop Bit
: 1
Code
: ASCII
Bit Format :
LSB
0
1
Start
Bit
Data Format:
1、
kg
G/N/T
.
W
.
Example
T.W. :
+ 1.000 kg
N.W. :
+ 1.000 kg
G.W. :
+ 2.000 kg
G = GROSS

8-4. RS-232 Input Format

Baud Rate : 2400、4800、9600
Data Bit
: 8
Parity
: N ( None )
Stop Bit
: 1
Code
: ASCII
The commands will be given by computer, and the functional formats
are as follows:
'R' = READ For reading the value of weight
'Z' = ZERO For zeroing
'T' = TARE For taring.
PAGE
30
2
3
+/-
N = NET
4
5
6
weight
MSB
7
8
Parity
k
g
JADEVER
http:www.jadever.com.tw
Stop
Bit
CR
LF