Advertisement

Quick Links

Part
Preparations before Usage
I
II
Part
Setting of Weighing Capacity & Accuracy
III
Sensitivity......
Part
Setting of Functional Parameters
IV
PAGE
0
CONTENTS
1-1. Precautions before Usage...........................
2-1. Main Functions Introductions.........................
3-1.Setting Operation........................................
3-2.Relation Between LOAD-CELL Output & Input
4-1.Enter into Parameter Setting............................
4-2.Description of Functional Parameters.............
JADEVER
http:www.jadever.com.tw
2
2
3
4
5
7
9
10
11

Advertisement

Table of Contents
loading

Summary of Contents for Jadever JWI600

  • Page 1: Table Of Contents

    2-2.Connection Between Display and Load Cell ……….… 2-3.Keypad Function and Panel Indication…………… Part Setting of Weighing Capacity & Accuracy 3-1.Setting Operation……………………….………… 3-2.Relation Between LOAD-CELL Output & Input Sensitivity…… Part Setting of Functional Parameters 4-1.Enter into Parameter Setting…………….………… 4-2.Description of Functional Parameters.………… JADEVER PAGE http:www.jadever.com.tw...
  • Page 2 VIII 8-1. RS-232+RTC board output pin….…… 8-2. Option Output 8-2-1. Printer Output.………………………….. 8-2-2. PC Output.…………………………………… 8-3. RS-232 Output Format………………………… 8-4. RS-232 Input Format……………………….. Appendix Part 1. Installation of Upright Pole…………………………. 2. Unit Conversion Table……………………….…………… 3. Optional Accessories………………………………… JADEVER PAGE http:www.jadever.com.tw...
  • Page 3: Precautions Before Usage

    ◎ Please select 110~240 VAC±10% 50/60HZ,6V4Ah BATTERY. Improper battery or ※ connection may cause system damage or other adverse effects. 1-2. Specifications and Characteristics Model JWI600 Input Sensitivity 0.13uV/DIV Input Voltage Range -0.5mV to 16.5mV Supply Voltage of Load 5V DC ±5%...
  • Page 4: Part Product Introduction & Installation

    6) Optional bilateral RS-232 or weight-checking signal output module. Both AC power and rechargeable battery are allowed. Built-in battery checking system can automatically find whether it requires recharging. Fast display, stable, accurate and easy operation. 2-2.Connection Between Display and Load Cell JADEVER PAGE http:www.jadever.com.tw...
  • Page 5 LOAD-CELL CONN Shield SIGNAL LOAD CELL CONNECTION SHIELD Solution to overlarge LOAD-CELL output: Add resistance LOAD-CELL 50k~500k ohm Solution to oversmall LOAD-CELL output: Add resistance LOAD-CELL 50k~500k ohm JADEVER PAGE http:www.jadever.com.tw...
  • Page 6: 2-3.Keypad Function And Panel Indication

    Gross weight symbol auxiliary unit Unit for simple counting and percentage kg unit Indicates steady usage. Accumulation symbol. Negative symbol Net weight symbol ZERO Zeroing symbol Low battery power indication. upper limit, OK and lower limit weight-checking mode JADEVER PAGE http:www.jadever.com.tw...
  • Page 7: Accumulation Display

    Pre-tare Accumulate Accumulation display Accumulation clearing :digit plus 1 : digit displacement :Function selection : enter into setting mode :exit setting mode :indicates press down the key once Part III Setting of Weighing Capacity & Accuracy JADEVER PAGE http:www.jadever.com.tw...
  • Page 8 Press the key , as shown at the right figure, the last zero is flashing; it is time to freely set the weighing capacity. Press the key : the flashing digit moves left. JADEVER PAGE http:www.jadever.com.tw...
  • Page 9 1⁄750 1⁄300 20,000 ------------ 1⁄10000 1⁄4000 1⁄2000 1⁄1000 1⁄400 25,000 ------------ 1⁄12500 1⁄5000 1⁄2500 1⁄1250 1⁄500 30,000 ------------ 1⁄15000 1⁄6000 1⁄3000 1⁄1500 1⁄600 40,000 ------------ ------------ 1⁄8000 1⁄4000 1⁄2000 1⁄800 50,000 ------------ ------------ 1⁄10000 1⁄5000 1⁄2500 1⁄1000 JADEVER PAGE http:www.jadever.com.tw...
  • Page 10 1⁄15000 3-2 Relation between LOAD-CELL Output & Input Sensitivity If the input accuracy of JWI600 display is higher than 0.13uv/D, it indicates that every one scale the accuracy changes, the required output voltage of load cell shall be more than 0.13uv/D. For the platform design, the output voltage of LOAD-CELL must match with the input accuracy of weight display unit, so the final design must conform to the following formats.
  • Page 11 If it is desired to continue to set main functional options, press the key Step 5: After finish all the settings, press the key to end the setting and return to weighing mode. JADEVER PAGE http:www.jadever.com.tw...
  • Page 12 ------------------------ Summary: Select t(ton) ------------------------ the unit to be used Init = kg immediately after lb(pound) ------------------------ scale Taiwan Jin ------------------------ powered on. HK Jin ------------------------ ------------------------ Power-off unit memory function UM OFF ☆ ON(enabled) Summary: JADEVER PAGE http:www.jadever.com.tw...
  • Page 13 9 are three backlight times minimum lit.Aut modes which can accuracy. effectively lit.ON No backlight enhance The backlight is lit all the convenience. lit.OFF time Zero Display No limit to zero display Zero.0 Zero.0 Range value JADEVER PAGE http:www.jadever.com.tw...
  • Page 14 Zero.4 displayed until at least 5 times accuracy placed on. In case that the display value is at the zero point, the value will not be Zero.5 displayed until at least 6 times accuracy placed on. JADEVER PAGE http:www.jadever.com.tw...
  • Page 15 Self-stick type, width of EZ2-S printer types are paper: 5cm*3cm also common ones Large LCD screen the market. Thermal sensitive dp-643 printer(BP-545) Give buzz Buzz selection for three-stage checking and weight-checking Bp.Un bp.Un weight articles function exceeds preset upper limit. JADEVER PAGE http:www.jadever.com.tw...
  • Page 16 ON( enabled) Rtc. OFF RTC function ☆ OFF(disabled) zero point tracking ☆ ON(enabled) function Summary: It can be used to improve TrA.ON ro point driftin OFF(disabled) caused by environmental or other disturbance. ON(enabled) Automatic tare A.t.OFF ☆ OFF(disabled) JADEVER PAGE http:www.jadever.com.tw...
  • Page 17 Under power-on status, put container or article to be ed on the pa n, and the screen will display the weight f the article, e.g. 1.000kg. Press the key complete the taring process, weight symbol ppears on the screen, which JADEVER PAGE http:www.jadever.com.tw...
  • Page 18 Press the key …… cyclically select the d igit to be changed. Press the key cyclically increase the value of flashing digit. Once finished, press the key to return to weighing mode. JADEVER PAGE http:www.jadever.com.tw...
  • Page 19 Press down the once again, and the screen will display the net weight of weighed articles. Take away the container and weighed articles. 5-4. Automatic Tare JADEVER PAGE http:www.jadever.com.tw...
  • Page 20 Press down the key once again, and the screen will display the value of net weight: 2.000kg, while the net weight symbol appears again. Take all tared and weighed articles away from the pan. JADEVER PAGE http:www.jadever.com.tw...
  • Page 21 It is allowed to accumulate for 99 times. For example, here accumulate for 8 times. Press the key screen will display the total accumulation times and total accumulation weight, then automatically return weighing mode. JADEVER PAGE http:www.jadever.com.tw...
  • Page 22: 5-7.Simple Counting & Percentage Calculation

    The sample quantity will not be saved after power-off. Press the key and then to shift to weighing unit, and then it will return to weighing mode. JADEVER PAGE http:www.jadever.com.tw...
  • Page 23 (1) Redo the step 2 to 5. Once the weight-checking value is set, press the key to return to normal weighing mode, now the scale is under weight-checking status. (2) While shifting to NC parameter, press the key JADEVER PAGE http:www.jadever.com.tw...
  • Page 24: 5-8.Weight-Checking

    Put proper weight on the pan, press the key begin to conduct the weight calibration when the screen displays the right figure. Until it gives an indicative sound, JADEVER PAGE http:www.jadever.com.tw...
  • Page 25: Error Message & Simple Troubleshooting

    EEPROM or contact service department. Err5 The weighed articles are overload (max. weighing Immediately take capacity: +9e) away the overload articles from the pan and JADEVER PAGE http:www.jadever.com.tw...
  • Page 26: External Interface

    RS-232 & RTC (time and date record) functional module onto one circuit board, so only this board can ensure the two functions can be realized. 8-1. RS-232+RTC board output pin RTC Function Setting Step Description Display JADEVER PAGE http:www.jadever.com.tw...
  • Page 27: Option Output

    8-2-1 Printer output: 2.1.1 Parameter Setting: Step Description Screen display Press the key after press and hold down the , release the key to enter into the setting mode, release the key until the screen displays CAL. JADEVER PAGE http:www.jadever.com.tw...
  • Page 28 PEri first then external device. …… Press cyclically set the external devices. There are SH-24, TP-24, AX-III, EZ2-S (Godex), TDP-643(BP-545) and Zebra printers available for selection. Press the key to return to normal weighing mode. JADEVER PAGE http:www.jadever.com.tw...
  • Page 29: Pc Output

    CAL. Press again to shift to RS-232 transmission function setting mode. Press the key cyclically transmission rate : 9600, 4800 and 2400. Press the key JADEVER PAGE http:www.jadever.com.tw...
  • Page 30 Universal 25 pin to 9 pin RS232 connecting cable. 2, 3 pin at one side requires exchange. Note: circle stands for male connector and bold dot stands for female connector. Cable connecting with LCD screen Universal 25 pin to 9 pin RS232 connecting cable. JADEVER PAGE http:www.jadever.com.tw...
  • Page 31: Rs-232 Output Format

    : 1 Code : ASCII The commands will be given by computer, and the functional formats are as follows: ‘R’ = READ For reading the value of weight ‘Z’ = ZERO For zeroing ‘T’ = TARE For taring. JADEVER PAGE http:www.jadever.com.tw...
  • Page 32: Part Appendix

    (11) pin Installation Steps: Put the cable of Load Cell on (1) upright pole mount through (2) upright pole, insert (2) upright pole into the hole of (1) upright pole mount and tighten the two (6) screws. JADEVER PAGE http:www.jadever.com.tw...
  • Page 33: Unit Conversion Table

    RS232 +RTC T.W. : + 2.375 kg N.W. : + 2.375 kg G.W. : + 4.750 kg → + RS232 +RTC → + TDP(BP545) T.W.: RS232 +RTC +0.0000 kg N.W.: → + +1.6025 kg G.W.: +1.6025 kg JADEVER PAGE http:www.jadever.com.tw...
  • Page 34 SH-24(TP-24) RS232 +RTC Only display the weight value. → LED Display RS232 +RTC → + JADEVER PAGE http:www.jadever.com.tw...

Table of Contents