Error Message & Simple Troubleshooting - Jadever JWI600 User Manual

Table of Contents

Advertisement

8
Press the key
finish setting and return to
normal weighing mode.
Part VII Error Message & Simple Troubleshooting
Error
message
Err
Beyond the display range
Err2
Initial zero point exceeds +30% (take 10% as
reference basis), 1. There is something on the pan;
2. There is interference from other articles; 3.
LOAD CELL failed.
-Err2
Initial zero point exceeds –30% (take 10% as
reference basis), 1. There is something on the pan;
2. There is interference from other articles; 3.
LOAD CELL failed.
Err3
Higher than A/D resolution range – FFFFF, 1. A/D
failed; 2. LOAD CELL failed
-Err3
Lower than A/D resolution range – XXXXX, 1. A/D
failed, 2. LOAD CELL failed
Err4
EEPROM Checksum error
Err5
The weighed articles are overload (max. weighing
capacity: +9e)
PAGE
24
to
Cause
Solutions
Reduce the
1. Take away the
articles that result
in interference. 2.
Replace LOAD
CELL or contact
department.
1. Take away the
articles that result
in interference. 2.
Replace LOAD
CELL or contact
department.
Replace LOAD
CELL or contact
department
Replace LOAD
CELL or contact
department
If the error
message appears
once again after
the scale is
powered on
again, please
re-weld EEPROM
or contact service
department.
Immediately take
away the
overload articles
from the pan and
JADEVER
http:www.jadever.com.tw
weight
service
service
service
service

Advertisement

Table of Contents
loading

Table of Contents