Fluke 1773 Calibration Manual page 24

3 phase power quality analyzer
Hide thumbs Also See for 1773:
Table of Contents

Advertisement

1773/1775/1777
Calibration Manual
Table 13. Clamp Current Probe Input Verification with 5500A/COIL
Type/Range
i40S-EL, Clamp 40A HIGH
i40S-EL, Clamp 40A HIGH
i40S-EL, Clamp 40A HIGH
i40S-EL, Clamp 40A LOW
i40S-EL, Clamp 40A LOW
i40S-EL, Clamp 40A LOW
i17xx-FLEX1.5KIP, Flexi 1500A HIGH
i17xx-FLEX1.5KIP, Flexi 1500A HIGH
i17xx-FLEX1.5KIP, Flexi 1500A HIGH
i17xx-FLEX1.5KIP, Flexi 1500A LOW
i17xx-FLEX1.5KIP, Flexi 1500A LOW
i17xx-FLEX1.5KIP, Flexi 1500A LOW
i17xx-FLEX3KIP, Flexi 3000A HIGH
i17xx-FLEX3KIP, Flexi 3000A HIGH
i17xx-FLEX3KIP, Flexi 3000A HIGH
i17xx-FLEX3KIP, Flexi 3000A LOW
i17xx-FLEX3KIP, Flexi 3000A LOW
i17xx-FLEX3KIP, Flexi 3000A LOW
i17xx-FLEX6KIP, Flexi 6000A HIGH
i17xx-FLEX6KIP, Flexi 6000A HIGH
i17xx-FLEX6KIP, Flexi 6000A HIGH
i17xx-FLEX6KIP, Flexi 6000A LOW
i17xx-FLEX6KIP, Flexi 6000A LOW
i17xx-FLEX6KIP, Flexi 6000A LOW
20
20 A
55x2A
Applied
Jack
Current
No
0.08 A
0.4 A
No
0.8 A
4 A
Yes
8 A
40 A
No
0.008 A
0.04 A
No
0.08 A
0.4 A
No
0.8 A
4 A
Yes
20 A
1000 A
Yes
10 A
500 A
No
2 A
100 A
No
2 A
100 A
No
0.2 A
10 A
No
0.02 A
1 A
Yes
20 A
1000 A
Yes
10 A
500 A
No
2 A
100 A
No
2 A
100 A
No
0.2 A
10 A
No
0.02 A
1 A
Yes
20 A
1000 A
Yes
10 A
500 A
No
2 A
100 A
No
2 A
100 A
No
0.2 A
10 A
No
0.02 A
1 A
Upper
Signal
Limit
0.4108
4.036
40.288
0.04108
0.4036
4.0288
1010.3
505.3
101.3
101.03
10.13
1.04
1010.9
505.9
101.9
101.09
10.19
1.10
1016.8
509.3
103.3
101.68
10.33
1.195
Lower Limit
0.3892
3.964
39.712
0.03892
0.3964
3.9712
989.7
494.7
98.7
98.97
9.87
0.96
989.1
494.1
98.1
98.91
9.81
0.90
983.2
490.7
96.7
98.32
9.67
0.805