Operating Panel; Before Commissioning The Appliance; Switching The Appliance On/Off; Led Status Display - Bosch Tronic 5000 Series Installation And Operating Instructions Manual

Electric instantaneous water heater
Table of Contents

Advertisement

Available languages

Available languages

4.1

Operating panel

Fig. 4
Operating panel
[1] Operating status LED
[2] Operating mode Bath
[3] Operating mode Dish Wash
[4] Maximum temperature
[5] Knob for selecting temperature / operating modes
[6] Minimum temperature
[7] Operating mode Hand Wash
[8] Operating mode Shower
4.2

Before commissioning the appliance

CAUTION
Risk of electric shock!
▶ The initial commissioning of the appliance must be carried
out by a qualified expert who will provide the client with all
the information required for its proper functioning.
NOTICE
Risk of damage to the appliance!
▶ Never turn on the appliance if there is no water. This could
damage the heating element.
4.3

Switching the appliance on/off

Switching On
▶ Turn on a hot water tap.
The appliance turns on. The water heats up while it
circulates through the appliance.
Switching Off
▶ Turn off the hot water tap.
Tronic 5000 – 6721830067 (2021/06)

4.3.1 LED status display

LED
Appliance status
Off
Appliance switched off
White LED
Appliance switched on
White LED flashes
The appliance is not reaching the set
(1x per second)
temperature. The appliance has reached
the power limit ( chapter
9).
White LED flashes
Automatic start-up air purge.
(2x per second)
Red LED
The appliance is malfunctioning (
chapter 9).
White LED flashes
The water inlet temperature is higher
4x
than the temperature selected on the
appliance (Solar). The appliance does
not heat up.
Table 2
4.4

Temperature control

This appliance has a temperature range for hot water from
20 °C (minimum) to 60 °C (maximum).
To select a hot water temperature from within this range, just:
▶ Turn the knob and select a hot water temperature of
between 20 °C and 60 °C.
To avoid unnecessary consumption of water, energy and
premature calcification of the appliance,
▶ Select the desired temperature on the appliance, rather
than mixing in cold water at the tap or shower outlet.
The device offers precise control of the temperature of drinking
water, which enables the direct supply to showers. If the device
is still operated with a thermostatic tap, the temperature
selected on the device must comply with the recommendations
of the thermostatic tap manufacturer, or, if this is unclear, a
temperature of 50 °C is recommended.

4.4.1 Operating modes

For using for Hand washing, Shower, Bath and Washing dishes,
there are the following recommended positions: