Configure The Power Level; Setting Maximum Temperature; Configuring And Installing A Priority Relay - Bosch Tronic 5000 Series Installation And Operating Instructions Manual

Electric instantaneous water heater
Table of Contents

Advertisement

Available languages

Available languages

Installation (only for approved contractors)

5.10.1 Configure the power level

▶ Use jumpers J2 and J3 to configure the power level of the
appliance, according to the table below.
TR... 11/
TR... 15/
13
18/21
13 kW
21 kW
(Factory
(Factory
Settings)
Settings)
18 kW
11 kW
15 kW
Table 6
Configuring the power
If the power of the appliance is changed,
▶ Check which flow limiter should be used ( chapter 10).

5.10.2 Setting maximum temperature

▶ Use Jumpers J4 and J5 to set the maximum temperature of
the appliance, according to the table below.
Max. Temperature
Maximum Temperature 60 °C
(Factory Settings)
Maximum Temperature 53 °C
(EN60335 - if the appliance
supplies water for showering)
22
TR... 21/
Jumpers: J2 - J3
24/27
27 kW
(Factory
Settings)
24 kW
21 kW
Jumpers: J4 - J5
Max. Temperature
Maximum Temperature 48 °C
Maximum Temperature 42 °C
Table 7
Setting maximum temperature

5.10.3 Configuring and installing a Priority Relay

For the appliance to work with a priority electric circuit, a
special priority relay (BZ 45L21) is required. Other types of
priority relays, with the exception of electronic priority relays,
may not work correctly.
Fig. 39
Wiring diagram
▶ Remove Jumper J1 to activate the Priority Relay mode in
the appliance's electronics system, see table below.
Tronic 5000 – 6721830067 (2021/06)
Jumpers: J4 - J5

Hide quick links:

Advertisement

Chapters

Table of Contents
loading