Dometic cool mate & cuddy dc Installation & Operation Manual page 22

Table of Contents

Advertisement

Fig. 11 Dedicated Power Module (DPM) Specs Tables for Use With Cuddy dc Systems Only
Electrical Specifications
Output Waveform ............................................... Modified Sine-Wave
Output Power ..................................................... 600W Continuous
Output Surge Rating ......................................... 1200W for 1 sec
Output Voltage ................................................... 115VAC ± 10%
Output Frequency ............................................. 60Hz (±4Hz)
Input DC Voltage Range ................................... 11 - 15VDC
Input Low Voltage Shutdown ............................ < 10.5VDC ± 0.2VDC
High Temperature Shutdown ............................ Thermistor ≥167°F (75°C)
Reverse Polarity Protection .............................. External Fuse
No Load Current Draw ...................................... 0.75A~0.95A
Efficiency ........................................................... ~90%
Over-voltage Shut-down ................................... 16-17VDC, restart below 16VDC
General Specifications
Isolation Voltage ................................................ Non-isolated
Operating Temperature Range ......................... -13 ~ 122°F (-25 ~ +50°C)
Storage Temperature Range ............................ -40 ~ 167°F (-40 ~ +75°C)
External Fuse .................................................... 30A x 2
Safety ................................................................. CE
Dimensions (L x W x H) .................................... 9.5 x 5.1 x 2.7" (241 x 130 x 69mm)
DC Input Connections (IN) ............................... Ring Terminals
Net Weight ......................................................... ~2.9 lbs (1.3kg)
AC Output Connections .................................... Per Dometic Wiring Diagram M8010112 in this manual
Ventilation .......................................................... Allow at least 1" (25mm) above unit for adequate airflow.
LED Lights Scheme for DPM (see note)
Battery Energy Level
Full (Battery Voltage>13V) ............................. Green ................. Green
Intermediate(12-13V) ..................................... Green ................. Orange
Low(<12V) ...................................................... Red .................... Red
Note: LED lights may or may not be readily visible, depending on DPM installation location. This table is included as a conve-
nience, but is not necessary for troubleshooting the system.
Fig. 12 DC Wire Sizing Table
L-2200
No Load
With Load
22

Advertisement

Table of Contents
loading

Table of Contents