Page 1
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 SUPPORT Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 INFORMATION Web site: www.blackbox.com • E-mail: info@blackbox.com...
Page 2
FCC STATEMENT FEDERAL COMMUNICATIONS COMMISSION INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication.
Page 3
T1 CSU/DSU (V.35, 449, or 530) INSTRUCCIONES DE SEGURIDAD (Normas Oficiales Mexicanas Electrical Safety Statement) 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
Page 4
TRADEMARKS TRADEMARKS USED IN THIS MANUAL Accunet and AT&T are registered trademarks of AT&T. UL is a registered trademark of Underwriters Laboratories Incorporated. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners. Registration Numbers FCC Registration Number (unit) .........GBRUSA-18888-DE-N ®...
Page 8
CHAPTER 1: Specifications Front-Panel Network Indicators - Loss Of Signal (LOS) - Bipolar Violations (BPV) - Synchronization - Red Alarm - Yellow Alarm - Test Front-Panel DTE Channel Indicators - Transmit Data (TD) - Receive Data (RD) - Request To Send (RTS) - Receive Line Signal Detect (RLSD) Mean Time Between Failure (Estimated) 40,000 hours...
The T1 CSU/DSU has a built-in CSU which complies with AT&T Publication 62411. This allows you to attach the T1 CSU/DSU directly to the T1 circuit. This CSU can be enabled or disabled with a simple switch setting so that the unit can act as a DSU or as a DSU/CSU. It can also be used as a high-speed line driver to extend high- speed data circuits up to 6000 feet (1828.8 m) over shielded twisted-pair (STP) cable.
CHAPTER 2: Introduction 2.3.1 R CSU/A EMOTE GGREGATE OOPBACK The Remote CSU/Aggregate Loopback (see Figure 2-1) test lets you verify the logic from the local interface through the remote aggregate and back to the local channel interface. To select this test, position the Aggregate Loopback switch in the Remote position.
GGREGATE OOPBACK The Local Aggregate Loopback diagnostic (Figure 2-4) lets you verify the T1 CSU/DSU logic from the channel interface, through the aggregate, and return to the channel interface. To select this test, position the Aggregate Loopback switch in the Local position. When complete, reposition the switch to the center position.
LBO Switch must be set to the 0 dB position. 2.7 Channel Interface Connections T1 CSU/DSU is configured for DTE connection with one of these three interfaces: V.35, RS-449, or RS-530 (female connectors). Below are the pinouts (male connectors) for these interfaces.
T1 CSU/DSU (V.35, 449, or 530) 2.7.1 P OWER ONNECTION The power connector (female) is on the rear panel. The male connector of the DC power supply plugs into this female connector. Figure 2-6 shows the pinout of the 5-pin DIN connector.
Before installing the T1 CSU/DSU, carefully read and understand the entire installation procedure. Although we take great care to make sure that the T1 CSU/DSU is properly packaged so that it will not be damaged during transit, it is your responsibility to verify that the unit arrives undamaged. Before unpacking the T1 CSU/DSU, read the following: 1.
Power to the T1 CSU/DSU is supplied by a separate DC power supply. Insert the power supply male DIN connector into the female DIN connector at the rear of the unit. Insert the power cable male connector into a...
T1 CSU/DSU (V.35, 449, or 530) 4. Operation The T1 CSU/DSU is controlled by a series of simple switch settings that the operator can select by accessing Switches one, two, and three at the rear of the unit. 4.1 Modify Configuration To configure a new T1 CSU/DSU Series or modify the configuration of an existing T1 CSU/DSU Series, first determine the correct information by reviewing the following worksheet.
Page 18
CHAPTER 4: Operation Configuration Worksheet Customer Name: __________________________________________________________ Date: __________________________________________________________________ Customer Location: ________________________________________________________ Configuration: ____________________________________________________________ Switch One Settings 1. Data Rate Selection (see Table 4-2) ..........S1-1 S1-2 S1-3 2. DTE Channel Multiples N x 56 kbps: ....S1-4: On N x 64 kbps: ....S1-4: Off Selectable N x 56 Rates: 8, 16, 24, 32, 40, 48, 56, 64, 112, 168, 192, 224, 280, 320, 336, 448, 560, 672, 840, 960, 1120, and 1344 kbps.
Page 19
T1 CSU/DSU (V.35, 449, or 530) 3. Channel Send Timing: Loop 1 (Terminal Timing) ........S1-5: On Loop 2 (Send Timing) ........S1-5: Off 4. Channel Timing: Normal ..............S1-6: On Inverted ..............S1-6: Off 5. Channel Data: Normal ..............S1-7: On Inverted ..............S1-7: Off 6.
Page 20
CHAPTER 4: Operation Switch Two Settings 1. LBO Setting. (Active only in the CSU mode of operation. When operating in the DSX-1 mode, the LBO switch must be in the 0 dB position.) Position the LBO switch as directed by the carrier: -1 5 dB -7.5 dB 0 dB...
Page 21
T1 CSU/DSU (V.35, 449, or 530) In making the following 5 selections, the operator defines the mode of operation as DSX-1 and also specifies the proper transmit output pulse. 4. Transmit Output Pulse: (DSX-1 Mode Only. If any of the output pulse selections are made, then the CSU selection is invalid.
Page 22
CHAPTER 4: Operation 1 in 48 ..............S3-6: Off S3-7: On S3-8: Off 1 in 64..............S3-6: Off S3-7: Off S3-8: Off None..............S3-6: On S3-7: N/A S3-8: N/A 6. Zero Byte Suppression: Inhibit..............S3-9: On Active ..............S3-9: Off 7. DS0 Mapping: A. Contiguous ..............S3-10: On B.
T1 CSU/DSU (V.35, 449, or 530) 4.2 Configuration Tables When you become proficient with the T1 CSU/DSU’s configuration procedures, it may be easier and simpler to use the configuration tables presented below (also available on the bottom of the device) to quickly configure the T1 CSU/DSU Series.
You will be informed of your right to file a complaint with the FCC. 4. If you experience trouble with the telephone equipment, please contact Black Box at 724-746-5500 for information on obtaining service or repairs.
Page 27
T1 CSU/DSU (V.35, 449, or 530) AFFIDAVIT FOR THE CONNECTION OF CUSTOMER PREMISES EQUIPMENT TO 1.544 Mbps AND/OR SUBRATE DIGITAL SERVICES. For work to be performed in the certified territory of ___________________________________________________________________________________________ (TELCO Name) State of: ___________________________________________________________________________________ County of: ________________________________________________________________________________...
Page 28
APPENDIX: FCC Documentation Requirements I attest that the operator(s)/maintainer(s) of the digital CPE responsible for the establishment, maintenance, and adjustment of the encoded analog content and billing information has (have) been trained to perform these functions by successfully completing one of the following (check all that apply): a.