Natural Gas Conversion
WARNING
Natural conversion should only be
performed by a qualified service technician.
2
2
2
2
2
1
Remove injectors using a 9/32" nut driver.
4
1
1
1
1
2
Install and tighten injectors.
20
All manuals and user guides at all-guides.com
1
Remove aluminum gas spreaders.
3
95
160
180
139
139
95
160
160
180
Reference chart to determine which injectors are
needed for each burner.
5
Replace aluminum flame spreaders.
Natural Gas Regulator Conversion
1
Disconnect electrical power and shut off gas.
3
Unscrew the plastic conversion plug from the cap
and turn over. Screw plug back into cap with the wide
section close to the cap.
5
Test gas pressure. When converting the regulator for different
settings, the function of the regulator must be checked at a pressure at
least 1" WC (249Pa) above the specified manifold pressure.
2
2
Unscrew regulator cap.
4
1
Replace regulator cap.
Note: After injectors replacement,
adjust the burner flame (See Low
Flame Adjustment in Electrical &
Gas Requirements section).
21