Maintenance; Fault Diagnostics; Front Panel Indicators - 360 Systems ImageServer 2000 Operation Manual

Table of Contents

Advertisement

Maintenance

Fault Diagnostics

Front Panel Indicators

The five LED indicators on the front panel are used to diagnose server fault conditions. The
meaning of each indicator is noted in the following table. During normal operation, all five
indicators will be on.
GENLOCK
OFF indicates that the Genlock setting
in the System menu is "Internal"
FLASHING indicates that Genlock is
selected in the System menu, but
there is no signal, or an invalid signal,
at the GENLOCK input connector.
POWER
FLASHING indicates that there is a
fault in the system power supply.
FANS
FLASHING indicates that there is a
fault of the internal chassis fan.
DRIVES
FLASHING indicates that there is a
fault in the system RAID array.
SYSTEM
FLASHING indicates that the CPU fan
is running slow, or stopped; or that the
CPU temperature or voltage is not
within manufacturer's specification.
Image Server 2000 Owner's Manual
All manuals and user guides at all-guides.com
Repairs should be performed only by qualified electronics
technicians.
Check the Genlock setting in the On-
Screen System menu.
Check the Genlock cable connections
or signal.
Shut down the Image Server and
contact 360 Systems Customer Support
for further hardware diagnosis.
Check the chassis fan operation.
Replace if necessary. Do not run the
Image Server without a working fan.
Check the RAID array status using
the utility under
START > System > RAID STATUS.
Shut down the Image Server and
contact 360 Systems Customer Support
for further hardware diagnosis.