Page 2
Shania Stewart Release based on T0007525_UG_ver1.0. Shania Stewart Removed “Confidential” from footers. March 22, 2022 Release Updated the product marketing name March 24, 2022 Release Shania Stewart throughout the document. Breeze/Breeze-V/Vivid+ User Guide T0007805_UG Version 1.2 TEKTELIC Communications Inc. Page 2 of 22...
Included Product and Installation Material ..............14 Safety Precautions ......................14 Unpacking and Inspection ....................14 Required Equipment for Installation ................14 Breeze/Breeze-V/Vivid+ Mounting ................14 Power Up, Commissioning, and Monitoring ................. 16 Required Equipment ...................... 16 Power Up/Down Procedure ................... 16 Operations, Alarms, and Management .................
Page 4
List of Tables Table 1-1: Transducers in Breeze/Breeze-V/Vivid+ ............... 7 Table 1-2: Breeze/Breeze-V/Vivid+ Specifications ................. 9 Table 4-1: Breeze/Breeze-V/Vivid+ Default Reporting Behavior ..........17 Breeze/Breeze-V/Vivid+ User Guide T0007805_UG Version 1.2 TEKTELIC Communications Inc. Page 4 of 22...
Page 5
Figure 1-3: The typical and maximal tolerance for %RH at 25°C ..........11 Figure 1-4: The typical and maximal tolerance for the temperature transducer at 25°C ... 11 Figure 4-1: Breeze/Breeze-V/Vivid+ With Marked LED Positions ..........18 Breeze/Breeze-V/Vivid+ User Guide T0007805_UG Version 1.2...
Page 6
OD ......Operational Description PCBA ......Printed Control Board Assembly PRNG ......Pseudo-Random Number Generator RF .......Radio Frequency RSSI ......Received Signal Strength Indicator Rx .......Receive SPI ......Serial Peripheral Interface Tx ........Transmit Breeze/Breeze-V/Vivid+ User Guide T0007805_UG Version 1.2 TEKTELIC Communications Inc. Page 6 of 22...
The Breeze/Breeze-V/Vivid+ is a multi-purpose LoRaWAN IoT sensor packed into a very small form factor. The Breeze, Breeze-V, and Vivid+ are all variants in the same sensor family, each with different sensing capabilities. The Sensor is ideal for monitoring and reporting CO concentration, human motion, temperature, humidity, light, and barometric air pressure in an indoor environment.
(a) Breeze Model (b) Vivid+/Breeze-V Models Figure 1-1: Breeze/Breeze-V/Vivid+ Enclosures Figure 1-2 shows the enclosure external interfaces for each model. Four indicator LEDs are present underneath the circular light pipe on the front of the enclosures. There are two push buttons accessible by pin through holes on the front of the enclosures.
Figure 1-2: Breeze/Breeze-V/Vivid+ External Interfaces 1.2 Specifications The Breeze/Breeze-V/Vivid+ specifications are listed in Table 1-2. Table 1-2: Breeze/Breeze-V/Vivid+ Specifications Parameter Specification Use environment Indoor commercial/residential only 0°C‒60°C Operating temperature Storage temperature -40°C‒60°C 5%‒95%, non-condensing Size 80 mm x 80 mm x 26 mm (without mounting clip)
Parameter Specification Sensor Lifetime Breeze model with optimum settings and baseline use case: • > 5.5 years with 2xAA LTC batteries Vivid+ model with optimal settings and baseline use case: • > 4.7 years with 2xAA LTC batteries Breeze-V model with optimal settings and baseline use case: •...
Figure 1-3 and Figure 1-4, respectively. Figure 1-3: The typical and maximal tolerance for %RH at 25°C Figure 1-4: The typical and maximal tolerance for the temperature transducer at 25°C Breeze/Breeze-V/Vivid+ User Guide T0007805_UG Version 1.2 TEKTELIC Communications Inc.
1.3.3 Barometer A barometer is included in the Breeze/Breeze-V/Vivid+ in order to measure the barometric air pressure. TE Connectivity’s MS5607-02BA03 is designed for low power applications while providing highly accurate measurements. The sensor can operate at full accuracy over a range of 300 hPa to 1100 hPa, and can communicate over I C or SPI protocols.
Page 13
FoV, people need to be closer to the sensor to be detected. The amount of IR radiation from a moving person, which is also impacted by the person’s clothing or type of skin cover, also plays an important role at determining the detection range. Breeze/Breeze-V/Vivid+ User Guide T0007805_UG Version 1.2 TEKTELIC Communications Inc.
2.3 Unpacking and Inspection The following should be considered during the unpacking of a new Breeze/Breeze-V/Vivid+: 1. Inspect the shipping carton and report any significant damage to TEKTELIC. 2. Unpacking should be conducted in a clean and dry location.
Page 15
This could cause the Sensor to accidently slip off the mount and fall. There are no orientation concerns when the Sensor is mounted to a horizontal surface. Breeze/Breeze-V/Vivid+ User Guide T0007805_UG Version 1.2 TEKTELIC Communications Inc.
3 Power Up, Commissioning, and Monitoring 3.1 Required Equipment No special equipment is required to power on the Breeze/Breeze-V/Vivid+. 3.2 Power Up/Down Procedure Once the sensor information has been added to the Network Server, pull out the battery tabs to engage the battery. The batteries must be removed to turn off the device, but the external reset button can be pushed to simply reset the device;...
4.2 Default Configuration If dynamic reporting mode is enabled, the default configuration of the Breeze/Breeze-V/Vivid+ is as shown in Table 4-1. If dynamic reporting mode is not enabled, the Sensor will act as if it is exclusively in active mode.
4.3 LED Behavior The Breeze/Breeze-V/Vivid+ is equipped with four LEDs: two green (G1 and G2), one yellow (Y1), and one red (R1). Figure 4-1 shows the placements of each LED relative to a user facing the Sensor for reference. Figure 4-1: Breeze/Breeze-V/Vivid+ With Marked LED Positions During the join procedure: •...
The reset is instant, i.e. the button does not need to be kept pushed. The reset restarts the microprocessor. All the FW load and configuration parameters in the Flash are remembered during the reset. Breeze/Breeze-V/Vivid+ User Guide T0007805_UG Version 1.2 TEKTELIC Communications Inc.
(1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. Breeze/Breeze-V/Vivid+ User Guide T0007805_UG Version 1.2 TEKTELIC Communications Inc. Page 20 of 22...
Page 21
(2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Cet appareil doit être installé et utilise à une distance minimale de 0.2 m du corps humain. Breeze/Breeze-V/Vivid+ User Guide T0007805_UG Version 1.2 TEKTELIC Communications Inc.
Need help?
Do you have a question about the BREEZE and is the answer not in the manual?
Questions and answers